Master Burner flange 4033.059
SKU 4033.059
Brand Master
Photos
Key specifications
| Connection diameter | 50 |
|---|---|
| Temperature range | -20.0-150.0 °C |
| material | heat-resistant metal |
| Working pressure | up to 3 bar |
| Features | reinforced fastening, vibration resistant |
| Application | burner mounting to fuel system |
—price on request
on order
shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Master Burner flange 4033.059 is a component used to mount the burner to the fuel system of compatible Master air heaters. It is made of heat-resistant metal and features reinforced fastening for vibration resistance. The flange has a connection diameter of 50 mm, operates at pressures up to 3 bar, and withstands temperatures from -20.0 to 150.0 °C. It ensures a hermetic seal to prevent fuel leakage and maintain stable system pressure.
Further details
| Application | burner mounting to fuel system |
|---|---|
| Features | reinforced fastening, vibration resistant |
| Material | heat-resistant metal |
Choosing and fitting
Parts of this type are selected by matching the connection diameter and mounting hole pattern to the burner and heater body. Before ordering, measure the existing flange's diameter and verify the bolt spacing. The flange must be compatible with the specific model and year of the heater, as listed in the manufacturer's compatibility chart. Installation involves removing the old flange, cleaning the mating surfaces, and securing the new flange with the appropriate fasteners.
Signs of failure
When flanges of this kind fail, common issues include fuel leaks at the connection point, which may be visible as wet spots or a fuel odor. Vibration can cause fasteners to loosen, leading to an unstable burner flame or intermittent operation. Overheating may warp the flange, causing misalignment and poor sealing. Check for cracks, deformation, or signs of fuel seepage around the flange.
Fits equipment
Master B360 (2012), B360 (2013), B360 (2017), BV170 (2012), BV290 (2012), BV290 UK 110V (2012), BV290 (2013), BV290 DUAL VOLTAGE, BV290 B360 (2012) B360 (2013) B360 (2017) BV170 (2012) BV290 (2012) BV290 UK 110V (2012) BV290 (2013) BV290 DUAL VOLTAGE BV290 (2017)Master B360 (2012)
All specifications
| Connection diameter | 50 |
|---|---|
| Temperature range | -20.0-150.0 °C |
| material | heat-resistant metal |
| Working pressure | up to 3 bar |
| Features | reinforced fastening, vibration resistant |
| Application | burner mounting to fuel system |
Part numbers
| SKU | 4033.059 |
|---|---|
| Additional article | 696.889.005 |