Honeywell Gas boiler control unit S4565CD1039U
SKU S4565CD1039U
Brand Honeywell
Photos
Key specifications
| Safety standard | EN 298, EN 60730-1 |
|---|---|
| Supply voltage | 220–240 V |
| Supported ignition systems | dbi and ip |
| EN 298 compliance | yes |
| Gas regulator compatibility | VK41 series |
| Integrated protection | yes |
| Flame monitoring | yes |
| Controlled components | main and pilot burners |
| Direct flame interaction | no |
| Connector on top | yes |
| Reset method | own or external reset button |
| Reset wait time | 15 s |
| Emergency protection | yes |
109.40 EUR
99.45EUR
in stock · 1
incl. 21% VAT · 82.19 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is a Honeywell S4565CD1039U gas boiler control unit, designed for use in gas boilers, heaters and water heaters with automatic ignition. It cooperates with Honeywell VK41 series gas regulators, providing ignition and flame monitoring for the main and pilot burners. The unit supports both direct burner ignition (dbi) and pilot burner ignition (ip) systems. It operates at 220–240 V and complies with EN 298 and EN 60730-1. The control unit includes integrated protection functions and can be reset via its own or an external reset button, with a 15-second wait between attempts. A connector on the top simplifies mounting onto the gas regulator.
Further details
| Application | gas boilers, heaters and water heaters equipped with an automatic ignition system |
|---|---|
| Control System | CVI (joint control and ignition system) |
| Installation Orientation | any direction within 90° from vertical |
Choosing and fitting
Burner control units of this type are selected by matching the supply voltage, the ignition system type (direct burner ignition or pilot burner ignition), and the gas regulator series they are designed to work with. Installation is straightforward: the unit is placed onto the gas regulator and secured via the connector on its top, and it can be oriented within a 90° angle in any direction from the vertical position of the two-position electric actuator. Before ordering, confirm that the unit's reset method (own or external button) and its safety standard certifications are acceptable for the equipment. Also verify that the controlled components (main and pilot burners) are those present in the application.
Fits equipment
Honeywell VK41
Honeywell VK41 series
All specifications
| Safety standard | EN 298, EN 60730-1 |
|---|---|
| Supply voltage | 220–240 V |
| Supported ignition systems | dbi and ip |
| EN 298 compliance | yes |
| Gas regulator compatibility | VK41 series |
| Integrated protection | yes |
| Flame monitoring | yes |
| Controlled components | main and pilot burners |
| Direct flame interaction | no |
| Connector on top | yes |
| Reset method | own or external reset button |
| Reset wait time | 15 s |
| Emergency protection | yes |
Part numbers
| SKU | S4565CD1039U |
|---|---|
| Additional article | 534.412.138 |