Honeywell Gas boiler control unit S4565D3023U

SKU S4565D3023U Model S4565D3023 Brand Honeywell

Photos

Key specifications

Applicationdbi or ip
Safety standardEN 298, EN 60730-1
Ignition typedirect or pilot
Fuelgas
Supply voltage220–240 V
Safety featureManual reset lockout
Extended ignition timepreset extended ignition time
Supported ignition systemsdbi, ip
EN 298 complianceyes
all specifications (9) ↓
187.06 EUR
170.05EUR
in stock · 1

incl. 21% VAT · 140.54 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This control box is an automatic gas burner control unit for use in gas boilers, heaters, and water heaters. It operates on a 220–240 V supply and supports both direct burner ignition (DBI) and pilot burner ignition (IP) systems. The unit communicates directly with Honeywell VK41 series gas regulators via a dedicated top connector. It provides preset extended ignition time and a manual reset lockout for safety. The control box is designed in accordance with EN 298 and EN 60730-1.

Further details

Airflow Control Relaydetects absence of airflow and starts fan
Standby behaviorstandby mode with fan running if no airflow during pre-purge

Choosing and fitting

Control boxes of this type are selected by matching the supply voltage, ignition system type (direct or pilot), and the gas regulator series. They attach to the regulator through a dedicated connector at the top; it must align with the regulator's mating connector. These units may be installed within a 90° angle in any direction from the vertical position of the two-position electric actuator. Before ordering, verify that the control box model is approved for the specific gas regulator model in the equipment.

Signs of failure

When this type of control box fails to sense a flame within the safe ignition time, it enters a lockout state requiring a manual reset. The reset can be performed with the built-in or external reset button, or by interrupting the power supply; wait at least 15 seconds between reset attempts. If the airflow control relay does not detect sufficient airflow during pre-purge, the unit remains in standby with the fan running. A flame loss during operation triggers a restart sequence with pre-purge; repeated interruptions may indicate a faulty flame sensor or wiring.

Fits equipment

Honeywell VK41 Honeywell VK41 series gas regulators

All specifications

Applicationdbi or ip
Safety standardEN 298, EN 60730-1
Ignition typedirect or pilot
Fuelgas
Supply voltage220–240 V
Safety featureManual reset lockout
Extended ignition timepreset extended ignition time
Supported ignition systemsdbi, ip
EN 298 complianceyes

Part numbers

SKUS4565D3023U
Additional article534.412.070
ModelS4565D3023