Honeywell Gas boiler control unit S4570BS1036U

SKU S4570BS1036U Model S4570BS1036 Brand Honeywell

Photos

Key specifications

Supply voltage220–240 V
Flame detector typeionization
Connector on topyes
Direct flame interactionno direct flame interaction
Controlled componentsmain and pilot burners
Integrated protectionintegrated protection functions
Based onHoneywell S4570BS1036B
Control systemCVI
Modificationsvarious modifications
all specifications (9) ↓
737.51 EUR
670.46EUR
in stock · 1

incl. 21% VAT · 554.10 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This gas boiler control unit is part of a combined control and ignition system (CVI) developed for automatic ignition equipment. It is based on the Honeywell S4570BS1036B ignition machine and is designed to work with gas regulators from the Honeywell VK41 series. The unit controls both the main burner and the pilot burner, using ionization flame detection. It requires a supply voltage of 220–240 V and features a connector on top for simplified wiring. The control unit has no direct flame interaction and integrates protection functions for the burner control system. Various modifications are available for different ignition systems.

Further details

Connector On Topconnector provided on the top of the regulator
Design featuresjoint control and ignition system (CVI)

Choosing and fitting

When replacing a control unit of this kind, confirm that the supply voltage matches the existing system and that the flame detection principle is ionization, as this affects compatibility with the burner. The unit must be compatible with the gas regulator series in use (for example, VK41 series). Mounting is simplified by the connector on the top of the regulator; the ignition regulator can be installed within a 90° angle in any direction from the vertical position of the two-position electric actuator. Before ordering, compare the base model and any modification designation with the original part to ensure the correct version for the ignition system.

Fits equipment

Honeywell VK41 Honeywell VK41 series

All specifications

Supply voltage220–240 V
Flame detector typeionization
Connector on topyes
Direct flame interactionno direct flame interaction
Controlled componentsmain and pilot burners
Integrated protectionintegrated protection functions
Based onHoneywell S4570BS1036B
Control systemCVI
Modificationsvarious modifications

Part numbers

SKUS4570BS1036U
Additional article534.412.028
ModelS4570BS1036