Brahma Control box 18001352
SKU 18001352
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Safety time | 3 s |
| Protection class (IP) | IP40 |
| Body material | plastic |
| Fuel | gas |
| Maximum boiler capacity | 120 kW |
| Burner motor rated current | 4 A |
| Alarm system rated current | 1 A |
| Ignition transformer secondary current | 2000 mA |
| Sensor voltage | 300 |
| Internal wiring | flexible unipolar conductors |
| Flame detection circuit | mounted on printed circuit board |
| Pre-purge time | 50 s |
| Net weight | 0.55 kg |
684.07 EUR
621.88EUR
in stock · 5
incl. 21% VAT · 513.95 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Control box 18001352 is a control unit for forced-draft gas burners, designed for boilers up to 120 kW. It operates at a supply voltage of 220 V and features a safety time of 3 seconds and a pre-purge time of 50 seconds. The unit supports a burner motor current of 4 A, an alarm current of 1 A, and an ignition transformer current of 2000 mA. It has a sensor voltage of 300 V, a protection class of IP40, and a net weight of 0.55 kg. The body is made of plastic, and internal wiring uses flexible unipolar conductors, with the flame detection circuit mounted on a printed circuit board. This control box fits the Brahma SR3/V model.
Further details
| Certification | DIN 4788, part 3; certification from the "laboratory of macintosh and thermotechnics at the studi ed esperienze center" in rome; approval of the ministry of internal affairs on fire safety |
|---|---|
| Construction type | components fixed on a pressed frame |
| Frame material | heat-resistant material with high dielectric resistance |
Choosing and fitting
Control boxes of this type are selected by matching the supply voltage, safety time, and pre-purge time to the burner's specifications. The physical dimensions and mounting configuration must align with the burner's housing, and the electrical connections for the motor, alarm, and ignition transformer must be compatible. Before ordering, verify the boiler capacity and ensure the control box's ratings meet or exceed the burner's requirements.
Signs of failure
When control boxes of this kind fail, common symptoms include the burner not starting, intermittent operation, or failure to ignite. The equipment may lock out, indicated by an alarm signal, or the flame detection circuit may not respond correctly. Check the supply voltage, wiring connections, and the condition of the flame sensor for faults.
Fits equipment
Brahma SR3/V
All specifications
| Supply voltage | 220 V |
|---|---|
| Safety time | 3 s |
| Protection class (IP) | IP40 |
| Body material | plastic |
| Fuel | gas |
| Maximum boiler capacity | 120 kW |
| Burner motor rated current | 4 A |
| Alarm system rated current | 1 A |
| Ignition transformer secondary current | 2000 mA |
| Sensor voltage | 300 |
| Internal wiring | flexible unipolar conductors |
| Flame detection circuit | mounted on printed circuit board |
| Pre-purge time | 50 s |
| Net weight | 0.55 kg |
Part numbers
| SKU | 18001352 |
|---|---|
| Additional article | 246.124.216 |