{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Control box 18094000

SKU 18094000 Brand Brahma

Photos

Key specifications

Supply voltage220 V
Flame detector typefc7/. fc8/ solar cells
Protection class (IP)IP40
Dimensions9.8x8.5x6.5 cm
Service life under maximum load250000
Power consumption6.5 W
External fuse4 A
Fueloil
Firing stagestwo-flame
Independent safety contacts2 contacts
Net weight0.24 kg
all specifications (11) ↓
271.52 EUR
246.84EUR
in stock · 5

incl. 21% VAT · 204.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma Control box 18094000 is a safety control box for oil burners, designed for two-flame operation. It operates on a 220 V supply voltage with a power consumption of 6.5 W. The device features two independent safety contacts and is compatible with FC7/FC8 solar cell flame detectors. It has a protection class of IP40, weighs 0.24 kg net, and measures 9.8x8.5x6.5 cm. The control box has a service life of 250,000 cycles under maximum load and requires an external fuse of 4 A.

Further details

Applicationmonoblock oil burners, high pressure washers, hot air generators, steam boilers, furnaces
Cycle Typere-short-term cycle, restart every 24 hours

Choosing and fitting

When selecting a control box of this type, ensure the supply voltage matches the burner system (e.g., 220 V). Verify the flame detector type (e.g., FC7/FC8) and the number of safety contacts required. The physical dimensions and mounting base must be compatible with the existing burner housing. Always compare the external fuse rating and power consumption with the system's specifications before installation.

Signs of failure

Common failures in control boxes of this kind include failure to ignite, intermittent shutdowns, or no response to flame loss. If the equipment does not start or locks out, check the external fuse, wiring connections, and the flame detector signal. A faulty control box may also cause the burner to cycle repeatedly or fail to enter the pre-purge phase.

All specifications

Supply voltage220 V
Flame detector typefc7/. fc8/ solar cells
Protection class (IP)IP40
Dimensions9.8x8.5x6.5 cm
Service life under maximum load250000
Power consumption6.5 W
External fuse4 A
Fueloil
Firing stagestwo-flame
Independent safety contacts2 contacts
Net weight0.24 kg

Part numbers

SKU18094000
Additional article246.124.173