Brahma Control box 37511002
SKU 37511002
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionization |
| Protection class (IP) | IP00 |
| Body material | plastic |
| Certification | CE |
| Fuel | gas |
| Cycle type | intermittent |
| External fuse | 3.15 A |
| Ignition type | direct or pilot |
| Maximum humidity | 95% at +40 °C |
| Built-in fuse | 4 A |
| Maximum cable length to room thermostat | 20 m |
| Maximum cable length for other cables | 1 m |
| Pre-purge time | 0 s |
| Net weight | 0.2 kg |
239.59 EUR
217.81EUR
in stock · 1
incl. 21% VAT · 180.01 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Control box 37511002 is a gas burner control unit with type designation 0694BP0610. It operates on a supply voltage of 220–240 V and has a safety time of 10 s, with no pre-purge time. The device uses an ionization flame detector and supports direct or pilot ignition. It is designed for intermittent cycle operation and is certified to CE standards. The control box has a plastic body, weighs 0.2 kg, and has an IP00 protection class.
Further details
| Application | combi boilers, heating systems, steam boilers, air heaters, infrared heaters, convectors, water heaters, furnaces and block burners |
|---|
Choosing and fitting
Control boxes of this type are selected based on supply voltage, safety time, flame detector type, and ignition method. Ensure the control box matches the burner's voltage and flame sensing requirements. The unit must be installed with correct phase and neutral connections, and the external fuse rating should be 3.15 A. The maximum cable lengths for thermostat and other components are 20 m and 1 m respectively.
Signs of failure
Common failures include malfunction due to incorrect phase-neutral wiring, which may cause the control box to enter manual reset mode. Voltage surges can damage the unit, but a built-in varistor provides some protection. If the flame detector signal is weak or the ionization current is below the minimum threshold, the burner may fail to ignite or lockout. Check the ionization cable for proper insulation and distance from power cables.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionization |
| Protection class (IP) | IP00 |
| Body material | plastic |
| Certification | CE |
| Fuel | gas |
| Cycle type | intermittent |
| External fuse | 3.15 A |
| Ignition type | direct or pilot |
| Maximum humidity | 95% at +40 °C |
| Built-in fuse | 4 A |
| Maximum cable length to room thermostat | 20 m |
| Maximum cable length for other cables | 1 m |
| Pre-purge time | 0 s |
| Net weight | 0.2 kg |
Part numbers
| SKU | 37511002 |
|---|---|
| Additional article | 246.124.222 |
| Type designation | 0694BP0610 |