Key specifications
| Supply voltage | 220 V |
|---|---|
| Safety time | 10 s |
| Protection class (IP) | IP40 |
| Body material | thermosetting plastic |
| Ambient temperature | -10–60 °C |
| Firing stages | one-, two-stage |
| Cycle type | non-permanent |
| Power consumption | 7 W |
| Time ts | 15 s |
| Delay between EVP and EV2 | 15 s |
| Ignition transformer voltage | 8 kV |
| Ignition transformer secondary current | 6 mA |
| Spark energy | 45 mJ |
| Weight with socket | 515 g |
| Valve contact rating | 2 A |
| Alarm contact rating | 1 A |
| Thermostat contact rating | 6 A |
| Burner capacity | 350 |
| Controlled restart interval | 24 hours |
| Self-monitoring function | yes |
| Construction type | pressed frame of thermosetting material |
606.32 EUR
551.20EUR
in stock · 1
incl. 21% VAT · 455.54 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This control unit for atmospheric gas burners is suitable for one- and two-stage burners up to 350 kW capacity. It operates on a 220 V supply, consumes 7 W, and has a safety time of 10 s, a ts time of 15 s, and a delay between EVP and EV2 of 15 s. The built-in ignition transformer produces 8 kV at 6 mA with 45 mJ spark energy. Contact ratings are 2 A for the valve circuit, 1 A for the alarm circuit, and 6 A for the thermostat circuit. Its enclosure is rated IP40 and the operating ambient temperature is -10 to 60 °C. The device uses a pressed frame of thermosetting plastic and weighs 515 g with socket; it runs in a non-permanent cycle, performs self-monitoring, and has a controlled restart interval of 24 hours.
Further details
| Internal wiring | flexible unipolar conductors, excluding flame detection circuit |
|---|
All specifications
| Supply voltage | 220 V |
|---|---|
| Safety time | 10 s |
| Protection class (IP) | IP40 |
| Body material | thermosetting plastic |
| Ambient temperature | -10–60 °C |
| Firing stages | one-, two-stage |
| Cycle type | non-permanent |
| Power consumption | 7 W |
| Time ts | 15 s |
| Delay between EVP and EV2 | 15 s |
| Ignition transformer voltage | 8 kV |
| Ignition transformer secondary current | 6 mA |
| Spark energy | 45 mJ |
| Weight with socket | 515 g |
| Valve contact rating | 2 A |
| Alarm contact rating | 1 A |
| Thermostat contact rating | 6 A |
| Burner capacity | 350 |
| Controlled restart interval | 24 hours |
| Self-monitoring function | yes |
| Construction type | pressed frame of thermosetting material |
Part numbers
| SKU | 18021002 |
|---|---|
| Additional article | 246.124.210 |
| Model | AT5 |