Brahma Burner control unit CE191.4 20658621
SKU 20658621
Model CE191.4
Brand Brahma
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP40 |
| Fuel | gas |
| Air supply | forced draft |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | electric reset (volatile lockout) |
| Flame monitoring | ionisation |
| Ambient temperature | -20–60 °C |
| Pre-purge time | 30 s |
| Net weight | 0.275 kg |
170.10 EUR
154.64EUR
in stock · 2
incl. 21% VAT · 127.80 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma CE191.4 burner control unit (SKU 20658621) is a control box for gas burners with forced draft, operating in intermittent mode. It manages ignition and flame monitoring via an ionisation electrode, with a safety time of 10 seconds and a pre-purge time of 30 seconds. The unit operates on 230 V supply voltage, has a protection class of IP40, and weighs 0.275 kg. It features an electric reset (volatile lockout) and reacts to flame loss in less than 1 second. The ambient temperature range is -20 to 60 °C, and the service life under maximum load is 250,000 cycles.
Further details
| Application | heating boilers, air heaters, infrared heaters, water heaters |
|---|
Choosing and fitting
When selecting a replacement control box of this type, verify the supply voltage, safety time, and pre-purge time match the burner's requirements. The flame detector type (ionisation) must be compatible with the existing sensor. Ensure the unit's protection class and ambient temperature range suit the installation environment. Mounting may require a separate base, and the wiring diagram is typically printed on the housing. Compare the timing parameters on the old unit's label with the new one before installation.
Signs of failure
Typical failures of such control boxes include loss of flame signal, leading to a safety lockout indicated by a red LED. The burner may fail to ignite or shut down unexpectedly. Check the ionisation electrode for cleanliness and proper positioning, and verify the gas supply and air supply are adequate. If the unit locks out, it may require a power cycle to reset, depending on the reset mode.
All specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP40 |
| Fuel | gas |
| Air supply | forced draft |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | electric reset (volatile lockout) |
| Flame monitoring | ionisation |
| Ambient temperature | -20–60 °C |
| Pre-purge time | 30 s |
| Net weight | 0.275 kg |
Part numbers
| SKU | 20658621 |
|---|---|
| Additional article | 246.124.033 |
| Model | CE191.4 |
| OEM equivalent | 20657621 |