Brahma Microprocessor-based controller CM11F 37100213
SKU 37100213
Model CM11F
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionisation |
| Country of origin | Italy |
| Certification | EN 298:1993/2003, CE |
| Fuel | gas |
| Firing stages | two-stage |
| Safety standard | EN 298 |
| Air supply | with or without fan |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Operating principle | microprocessor-based controller |
| External fuse | 3.15 A |
| Flame monitoring | ionisation |
| Operating voltage | 220-240 V AC |
| Microprocessor-based | yes |
| Catalogue article numbers | 37100213, 246.124.078 |
| EN 298 compliance | yes |
| Pre-purge time | 1.5 s |
170.90 EUR
155.36EUR
in stock · 3
incl. 21% VAT · 128.40 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma CM11F is a microprocessor-based controller (burner management unit) designed for automatic ignition control, flame monitoring, and safe operation of two-stage atmospheric gas burners in intermittent mode. It operates on 220–240 V AC and supports burners with or without a fan. The unit features a pre-purge time of 1.5 seconds, a safety time of 10 seconds, and uses ionisation for flame detection with a reaction time of less than 1 second. It includes a manual lockout reset and is certified to EN 298:1993/2003 and CE standards. The controller has a service life of over 250,000 cycles under maximum load and requires an external fuse rated at 3.15 A.
Further details
| Application Type | automatic ignition control, flame monitoring and safe operation |
|---|
Choosing and fitting
When selecting a control box of this type, verify the supply voltage (e.g., 220–240 V AC), safety time, pre-purge time, and flame detection method (ionisation) match the burner's specifications. Ensure the controller supports the burner's stage configuration (e.g., two-stage) and air supply type (with or without fan). Mounting may involve DIN rail or panel installation; check the housing dimensions and connection base compatibility. Compare the article number (e.g., 37100213) with the existing unit's marking before ordering.
Signs of failure
Typical failures of such controllers include lockout due to flame loss, ignition failure, or open ionisation circuit, indicated by the reset button popping out. The equipment may fail to start or shut down unexpectedly, often requiring manual reset after addressing the cause. Check the ionisation electrode for contamination or incorrect gap, and verify the external fuse (rated up to 3.15 A) is intact. Intermittent operation requires a forced stop at least once every 24 hours to prevent premature wear.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionisation |
| Country of origin | Italy |
| Certification | EN 298:1993/2003, CE |
| Fuel | gas |
| Firing stages | two-stage |
| Safety standard | EN 298 |
| Air supply | with or without fan |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Operating principle | microprocessor-based controller |
| External fuse | 3.15 A |
| Flame monitoring | ionisation |
| Operating voltage | 220-240 V AC |
| Microprocessor-based | yes |
| Catalogue article numbers | 37100213, 246.124.078 |
| EN 298 compliance | yes |
| Pre-purge time | 1.5 s |
Part numbers
| SKU | 37100213 |
|---|---|
| Additional article | 246.124.078 |
| Model | CM11F |