Brahma Microprocessor-based controller CM11F 37100213

SKU 37100213 Model CM11F Brand Brahma

Photos

Key specifications

Supply voltage220–240 V
Safety time10 s
Flame detector typeionisation
Country of originItaly
CertificationEN 298:1993/2003, CE
Fuelgas
Firing stagestwo-stage
Safety standardEN 298
Air supplywith or without fan
Service life under maximum load250000
Cycle typeintermittent
Flame detection methods supportedionisation
Flame loss reaction timeless than 1 second
Safety featuremanual lockout reset
Operating principlemicroprocessor-based controller
External fuse3.15 A
Flame monitoringionisation
Operating voltage220-240 V AC
Microprocessor-basedyes
Catalogue article numbers37100213, 246.124.078
EN 298 complianceyes
Pre-purge time1.5 s
all specifications (22) ↓
170.90 EUR
155.36EUR
in stock · 3

incl. 21% VAT · 128.40 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma CM11F is a microprocessor-based controller (burner management unit) designed for automatic ignition control, flame monitoring, and safe operation of two-stage atmospheric gas burners in intermittent mode. It operates on 220–240 V AC and supports burners with or without a fan. The unit features a pre-purge time of 1.5 seconds, a safety time of 10 seconds, and uses ionisation for flame detection with a reaction time of less than 1 second. It includes a manual lockout reset and is certified to EN 298:1993/2003 and CE standards. The controller has a service life of over 250,000 cycles under maximum load and requires an external fuse rated at 3.15 A.

Further details

Application Typeautomatic ignition control, flame monitoring and safe operation

Choosing and fitting

When selecting a control box of this type, verify the supply voltage (e.g., 220–240 V AC), safety time, pre-purge time, and flame detection method (ionisation) match the burner's specifications. Ensure the controller supports the burner's stage configuration (e.g., two-stage) and air supply type (with or without fan). Mounting may involve DIN rail or panel installation; check the housing dimensions and connection base compatibility. Compare the article number (e.g., 37100213) with the existing unit's marking before ordering.

Signs of failure

Typical failures of such controllers include lockout due to flame loss, ignition failure, or open ionisation circuit, indicated by the reset button popping out. The equipment may fail to start or shut down unexpectedly, often requiring manual reset after addressing the cause. Check the ionisation electrode for contamination or incorrect gap, and verify the external fuse (rated up to 3.15 A) is intact. Intermittent operation requires a forced stop at least once every 24 hours to prevent premature wear.

All specifications

Supply voltage220–240 V
Safety time10 s
Flame detector typeionisation
Country of originItaly
CertificationEN 298:1993/2003, CE
Fuelgas
Firing stagestwo-stage
Safety standardEN 298
Air supplywith or without fan
Service life under maximum load250000
Cycle typeintermittent
Flame detection methods supportedionisation
Flame loss reaction timeless than 1 second
Safety featuremanual lockout reset
Operating principlemicroprocessor-based controller
External fuse3.15 A
Flame monitoringionisation
Operating voltage220-240 V AC
Microprocessor-basedyes
Catalogue article numbers37100213, 246.124.078
EN 298 complianceyes
Pre-purge time1.5 s

Part numbers

SKU37100213
Additional article246.124.078
ModelCM11F