Brahma Microprocessor-based controller CM191N.2 20083301
SKU 20083301
Model CM191N.2
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | ionization |
| Protection class (IP) | IP00 |
| Body material | impact-resistant plastic |
| Country of origin | Italy |
| Certification | EN 298:2003, CE |
| Fuel | gas |
| Firing stages | progressive (modulating) |
| Safety standard | EN 298 |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionization |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Installation position | any |
| EN 298 compliance | yes |
197.25 EUR
179.32EUR
in stock · 3
incl. 21% VAT · 148.20 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma CM191N.2 is a microprocessor-based controller (burner management unit) designed for automatic ignition control, flame monitoring, and safe operation of atmospheric gas burners with progressive (modulating) power control. It operates in intermittent mode and supports ionization flame detection, with a flame loss reaction time of less than 1 second. The unit features a manual lockout reset and is certified to EN 298:2003, with CE marking. It operates on a supply voltage of 220–240 V, has a protection class of IP00, and is housed in impact-resistant plastic. The controller is suitable for use with gas burners from various brands, including Riello, Baltur, Weishaupt, and Lamborghini.
Further details
| Air Supply | forced air supply (with fan) and without |
|---|
Choosing and fitting
When selecting a replacement control box of this type, ensure the supply voltage, flame detection method (ionization), and safety standards (EN 298) match the existing system. Verify the timing parameters (pre-purge, safety, and waiting times) as they vary by model and must align with the burner's requirements. The unit can be mounted in any position, typically on a DIN rail or with screws, and requires installation in a protective enclosure due to its IP00 rating. Always compare the marking on the old unit with the specifications of the new one before purchase.
Signs of failure
Common failures in control boxes of this kind include lockout due to flame loss or ignition failure, often indicated by the unit entering a manual reset state. Symptoms may include the burner failing to start, shutting down unexpectedly, or not responding to reset attempts. Check the ionization electrode for proper positioning and cleanliness, and verify the supply voltage and wiring connections. If the unit repeatedly locks out, inspect the flame detection circuit and ensure the gas supply is consistent.
Fits equipment
multiple burners from Riello, Baltur, Weishaupt, Lamborghini and other brands
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | ionization |
| Protection class (IP) | IP00 |
| Body material | impact-resistant plastic |
| Country of origin | Italy |
| Certification | EN 298:2003, CE |
| Fuel | gas |
| Firing stages | progressive (modulating) |
| Safety standard | EN 298 |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionization |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Installation position | any |
| EN 298 compliance | yes |
Part numbers
| SKU | 20083301 |
|---|---|
| Additional article | 246.124.036 |
| Model | CM191N.2 |