Brahma Microprocessor-based controller CM31F 37106218
SKU 37106218
Model CM31F
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 5 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Body material | impact-resistant, self-extinguishing plastic |
| Air supply | forced draught |
| Certification | CE, EN 298:2003 |
| Fuel | gas |
| Firing stages | progressive (modulating) |
| Safety standard | EN 298:2003 |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | non-volatile lockout with manual reset |
| Installation position | any |
| Flame monitoring | ionisation |
| EN 298 compliance | yes |
| Pre-purge time | 10 s |
198.85 EUR
180.77EUR
in stock · 4
incl. 21% VAT · 149.40 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma CM31F is a microprocessor-based controller (burner management unit) from the Eurobox series, designed for automatic ignition control, flame monitoring, and safe operation of forced-draught gas burners. It operates in intermittent mode and is suitable for progressive (modulating) burners. This model features a pre-purge time of 10 seconds and a safety time of 5 seconds, with flame detection via ionisation. It has a supply voltage of 220–240 V, protection class IP00, and is certified to CE and EN 298:2003. The controller includes a non-volatile lockout with manual reset and has a service life of over 250,000 cycles under maximum load.
Choosing and fitting
Parts of this type are selected by matching the supply voltage, safety time, pre-purge time, and flame detection method to the burner's requirements. The controller must be compatible with the burner's fuel type and stage control (e.g., progressive/modulating). Installation involves mounting the controller in any position, typically on a DIN rail or with screws, and connecting the ionisation electrode and ignition transformer. Ensure the controller's timing parameters align with the burner's specifications before ordering.
Signs of failure
Common failure modes for controllers of this kind include failure to ignite, lockout without flame, or repeated lockouts. Symptoms may include the burner not starting, shutting down during operation, or requiring manual reset frequently. Check the ionisation electrode for contamination or wear, verify the flame detection circuit, and inspect the controller's fuse and varistor for damage.
Fits equipment
multiple burners from Riello, Baltur, Weishaupt, Lamborghini and other brands
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 5 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Body material | impact-resistant, self-extinguishing plastic |
| Air supply | forced draught |
| Certification | CE, EN 298:2003 |
| Fuel | gas |
| Firing stages | progressive (modulating) |
| Safety standard | EN 298:2003 |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | non-volatile lockout with manual reset |
| Installation position | any |
| Flame monitoring | ionisation |
| EN 298 compliance | yes |
| Pre-purge time | 10 s |
Part numbers
| SKU | 37106218 |
|---|---|
| Additional article | 246.124.084 |
| Model | CM31F |