Brahma Control box CM31F 37106240
SKU 37106240
Model CM31F
Brand Brahma
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Certification | CE, EN298:1993, EN298:2003 |
| Fuel | gas |
| Firing stages | progressive (modulating) |
| connection_type | Molex-type connectors |
| Safety standard | EN298:1993, EN298:2003 |
| Air supply | forced draft |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Application type | atmospheric gas burners |
| Installation position | any |
| Pre-purge time | 20 s |
180.49 EUR
164.08EUR
in stock · 5
incl. 21% VAT · 135.60 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Control box CM31F 37106240 is a microprocessor-based burner management unit for atmospheric gas burners with forced draft, operating in progressive (modulating) mode. It features a supply voltage of 230 V, a safety time of 10 seconds, and a pre-purge time of 20 seconds. Flame detection is via ionisation, with a flame loss reaction time of less than 1 second. The device includes a manual lockout reset and is certified to CE, EN298:1993, and EN298:2003. It is designed for intermittent cycle operation and has a service life of 250,000 cycles under maximum load. Connection is via Molex-type connectors, and it fits multiple Riello, Baltur, Weishaupt, and Lamborghini burners.
Further details
| Application | heating systems, climate control, industrial installations |
|---|
Choosing and fitting
Parts of this type are selected by matching the supply voltage, safety time, pre-purge time, and flame detection method to the burner's specifications. The control box must be compatible with the burner's fuel type and air supply configuration. Installation involves mounting in any position, but due to IP00 protection, it must be enclosed in a protective cabinet. Wiring must follow the diagram on the housing, and the flame sensor must provide a stable signal. Ensure the connection type (e.g., Molex) matches the existing harness.
Signs of failure
Common failures include lockout due to ignition failure or flame loss, indicated by a red LED. The equipment may fail to start or shut down unexpectedly. Check the ionisation electrode for contamination or wear, verify gas supply and valve operation, and inspect wiring connections for integrity. A faulty control box may also cause intermittent operation or no response to reset.
Fits equipment
multiple Riello, Baltur, Weishaupt, Lamborghini
All specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Certification | CE, EN298:1993, EN298:2003 |
| Fuel | gas |
| Firing stages | progressive (modulating) |
| connection_type | Molex-type connectors |
| Safety standard | EN298:1993, EN298:2003 |
| Air supply | forced draft |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Application type | atmospheric gas burners |
| Installation position | any |
| Pre-purge time | 20 s |
Part numbers
| SKU | 37106240 |
|---|---|
| Additional article | 246.124.086 |
| Model | CM31F |