Key specifications

Supply voltage230 V
Safety time15 s
Flame detector typeionization
Protection class (IP)IP00
Body materialplastic, self-extinguishing
Fuelgas
Safety standardEN298
Flame detection methods supportedionization
Safety featuremanual reset lockout
Flame monitoringionization
Pre-purge time30 s
Net weight0.2 kg
all specifications (12) ↓
287.50 EUR
261.36EUR
in stock · 2

incl. 21% VAT · 216.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma Control box CM32F 37109241 is a gas burner control unit designed for automatic operation of gas burners with a fan. It operates at a supply voltage of 230 V and features a safety time of 15 seconds and a pre-purge time of 30 seconds. Flame detection is based on ionization, and the unit includes a manual reset lockout for safety. The control box is made of self-extinguishing plastic, has a net weight of 0.2 kg, and meets the EN298 safety standard. It is intended for gas fuel applications.

Further details

Applicationsteam convectors, heating boilers, warm air generators, radiator tubular heaters, water heaters

Choosing and fitting

Control boxes of this type are selected based on supply voltage, safety time, pre-purge time, and flame detection method. The mounting form and dimensions must match the existing burner or boiler configuration. Before ordering, verify the electrical connections and ensure compatibility with the flame detector type (ionization). The control box must be installed by a qualified technician, following the manufacturer's wiring diagram and safety regulations.

Signs of failure

Common failures of such control boxes include lockout due to flame detection issues, which may manifest as the burner failing to start or shutting down during operation. Symptoms can include repeated ignition attempts without flame establishment, or the system going into a manual reset state. Check the ionization electrode and its cable for damage or poor connection, and verify the supply voltage and wiring integrity.

All specifications

Supply voltage230 V
Safety time15 s
Flame detector typeionization
Protection class (IP)IP00
Body materialplastic, self-extinguishing
Fuelgas
Safety standardEN298
Flame detection methods supportedionization
Safety featuremanual reset lockout
Flame monitoringionization
Pre-purge time30 s
Net weight0.2 kg

Part numbers

SKU37109241
Additional article246.124.232
ModelCM32F