Brahma Control box DMN12PR 37521005
SKU 37521005
Model DMN12PR
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 3 s |
| Protection class (IP) | IP00 |
| Body material | plastic |
| Certification | CE, EN 298, EN 230:2005 |
| Fuel | gas or oil |
| External fuse | 3.15 A |
| Ignition type | direct or pilot ignition |
| Maximum humidity | 95% at +40 °C |
| Built-in fuse | 4 A |
| Maximum cable length to room thermostat | 20 m |
| Maximum cable length to remote alarm | 20 m |
| Maximum cable length for other cables | 1 m |
| Independent safety contacts | 2 contacts |
| Custom module connection | yes |
| Pre-purge time | 5 s |
| Net weight | 0.2 kg |
259.55 EUR
235.95EUR
in stock · 1
incl. 21% VAT · 195.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma DMN12PR control box (SKU 37521005) is a gas firing device designed for controlling atmospheric gas and liquid fuel burners in systems with non-constant operation cycles. It features automatic ignition with manual reset, supports direct or pilot ignition, and operates at a supply voltage of 220–240 V. The safety time is 3 seconds, and the pre-purge time is 5 seconds. It has two independent safety contacts for gas valve control, a built-in fuse of 4 A, and an external fuse of 3.15 A. The control box is certified to CE, EN 298, and EN 230:2005, and is suitable for gas or oil fuel types.
Choosing and fitting
Control boxes of this type are selected by matching the supply voltage, safety time, and pre-purge time to the burner's requirements. The unit must be compatible with the ignition type (direct or pilot) and the fuel type (gas or oil). Installation requires correct phase and neutral connection, proper grounding, and adherence to national electrical standards. The maximum cable lengths for external components are 20 m for thermostat and remote alarm, and 1 m for other cables, with the ignition cable kept as short and straight as possible.
Signs of failure
Common failures include malfunction due to incorrect phase-neutral connection, which may cause the controller to operate in manual reset mode at the end of the start-up safety time. Voltage fluctuations can damage the varistor, leading to unstable operation. Symptoms may include failure to ignite, repeated lockouts, or no response to reset attempts. Check cable connections, grounding, and the integrity of the built-in and external fuses.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 3 s |
| Protection class (IP) | IP00 |
| Body material | plastic |
| Certification | CE, EN 298, EN 230:2005 |
| Fuel | gas or oil |
| External fuse | 3.15 A |
| Ignition type | direct or pilot ignition |
| Maximum humidity | 95% at +40 °C |
| Built-in fuse | 4 A |
| Maximum cable length to room thermostat | 20 m |
| Maximum cable length to remote alarm | 20 m |
| Maximum cable length for other cables | 1 m |
| Independent safety contacts | 2 contacts |
| Custom module connection | yes |
| Pre-purge time | 5 s |
| Net weight | 0.2 kg |
Part numbers
| SKU | 37521005 |
|---|---|
| Additional article | 246.124.965 |
| Model | DMN12PR |
| Type designation | 0694BP0610 |