Key specifications
| Supply voltage | 100–240 V |
|---|---|
| Safety time | 30 s |
| Flame detector type | ionization |
| Country of origin | Italy |
| Firing stages | multi-stage |
| Air supply | atmospheric |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame loss reaction time | <1 |
| Installation position | any |
| Flame monitoring | ionization |
| Pre-purge time | 1.5 s |
313.05 EUR
284.59EUR
in stock · 1
incl. 21% VAT · 235.20 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma ECE113 control box (SKU 40000050) is a microprocessor-based controller for automatic ignition, flame monitoring, and safe operation of atmospheric gas burners with multi-stage power regulation. It operates in intermittent mode, with a supply voltage of 100–240 V, a safety time of 30 seconds, and a pre-purge time of 1.5 seconds. Flame detection is via ionization, with a flame loss reaction time of less than 1 second. The device is designed for a service life of 250,000 cycles under maximum load and can be installed in any position. It is manufactured in Italy.
Further details
| Application | industrial and domestic gas boilers, heat generators, air heaters, gas furnaces, drying chambers |
|---|
Choosing and fitting
Parts of this type are selected by matching the control box's supply voltage, safety time, pre-purge time, and flame detection method to the burner's specifications. Installation involves connecting the ionization electrode and ensuring the control box is compatible with the burner's stage control and air supply type. The mounting position is flexible, but the electrical connections and reset method must be verified against the existing wiring and control requirements.
Signs of failure
Common failure modes for this kind of control box include failure to ignite, lockout without flame establishment, or unexpected shutdowns during operation. Symptoms may include the burner not starting, repeated reset attempts, or the control box entering a fault state. Check the ionization electrode for contamination or incorrect gap, verify the supply voltage, and inspect for loose connections or damaged components.
All specifications
| Supply voltage | 100–240 V |
|---|---|
| Safety time | 30 s |
| Flame detector type | ionization |
| Country of origin | Italy |
| Firing stages | multi-stage |
| Air supply | atmospheric |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame loss reaction time | <1 |
| Installation position | any |
| Flame monitoring | ionization |
| Pre-purge time | 1.5 s |
Part numbers
| SKU | 40000050 |
|---|---|
| Additional article | 246.124.269 |
| Model | ECE113 |