{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Control box SM592N.2 36223151

SKU 36223151 Model SM592N.2 Brand Brahma

Photos

Key specifications

Supply voltage220–240 V
Safety time3–60 s
Flame detector typeionization
Protection class (IP)IP 00
Body materialplastic
Fuelgas
Independent safety contacts2 contacts
Pre-purge time1.5–40 s
Net weight0.17 kg
all specifications (9) ↓
price on request
on order

shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma SM592N.2 control box is a gas burner control unit designed for atmospheric burners in intermittent operation, with or without a fan. It operates on a supply voltage of 220–240 V and uses ionization flame detection. The device features a safety time adjustable from 3 to 60 seconds and a pre-purge time from 1.5 to 40 seconds. It includes two independent safety contacts for gas valve control and is housed in a plastic body with IP 00 protection. The net weight is 0.17 kg.

Choosing and fitting

When selecting a control box of this type, ensure the supply voltage matches the system (e.g., 220–240 V). The safety time and pre-purge time must be compatible with the burner's requirements. The flame detector type (ionization) must correspond to the burner's electrode configuration. The control box should be mounted in a location that does not require higher than IP 00 protection, and the electrical connections must match the wiring diagram of the existing unit.

Signs of failure

Common failures of such control boxes include failure to start, lockout after safety time, or intermittent operation. Symptoms may include the burner not igniting, the system going into lockout mode, or the flame signal being lost during operation. Check the ionization electrode, wiring, and supply voltage. If the control box does not reset after a lockout, it may be faulty.

All specifications

Supply voltage220–240 V
Safety time3–60 s
Flame detector typeionization
Protection class (IP)IP 00
Body materialplastic
Fuelgas
Independent safety contacts2 contacts
Pre-purge time1.5–40 s
Net weight0.17 kg

Part numbers

SKU36223151
Additional article246.124.107
ModelSM592N.2