Brahma Control box SM592N.2 36283961
SKU 36283961
Model SM592N.2
Brand Brahma
Photos
Key specifications
| Flame detector type | ionization |
|---|---|
| Flame detection methods supported | ionisation, uv, or ir |
| Flame loss reaction time | less than 1 second |
| EN 298 compliance | meeting en 298 requirements |
| Combustion monitoring | yes |
—price on request
on order
shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma SM592N.2 control box (SKU 36283961) is a microprocessor-based burner automation controller for automatic ignition, flame monitoring, and safe operation of atmospheric gas burners, both single-stage and two-stage. It operates in intermittent cycle and is suitable for burners with natural draught or forced air supply. The device supports flame detection via ionization, UV, or IR methods, with a flame loss reaction time of less than 1 second, meeting EN 298 requirements. It includes combustion monitoring and performs a full sequence: checking for false flame, pre-purge, ignition, and safe shutdown upon flame loss.
Further details
| Automatic Cycle | full automation of the combustion cycle |
|---|
Choosing and fitting
Parts of this type are selected by exact series and type designation, supply voltage, safety and pre-purge times, flame detection method (ionisation, UV, or IR), and base or plug pattern. Controls from different series are normally not interchangeable, even within the same brand. When replacing, verify that the replacement matches the original exactly on these parameters, particularly voltage and safety time settings. For burners using an ionisation electrode, the control must be compatible with that detection method.
Signs of failure
Items of this kind may fail due to internal component degradation, leading to lockout in abnormal situations such as no flame, ionization circuit break, or ignition failure. Symptoms include the burner failing to start, shutting down unexpectedly, or not responding to reset attempts. Check the control box for proper voltage supply, flame detector signal, and correct wiring connections.
All specifications
| Flame detector type | ionization |
|---|---|
| Flame detection methods supported | ionisation, uv, or ir |
| Flame loss reaction time | less than 1 second |
| EN 298 compliance | meeting en 298 requirements |
| Combustion monitoring | yes |
Part numbers
| SKU | 36283961 |
|---|---|
| Additional article | 246.124.182 |
| Model | SM592N.2 |