Brahma Control box SM592N/S 36223321

SKU 36223321 Model SM592N/S Brand Brahma

Photos

Key specifications

Flame detector typeionization
Automatic cyclefull automation
Heat demand inputthermostat or controller
all specifications (3) ↓
219.62 EUR
199.65EUR
in stock · 21

incl. 21% VAT · 165.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma SM592N/S control box (SKU 36223321) is a microprocessor-based burner automation device for automatic ignition control, flame monitoring, and safe operation of atmospheric gas burners. It supports both single-stage and two-stage burners, operates in intermittent cycle, and is suitable for burners with natural draft or forced air supply. The unit performs full automation of the combustion cycle, including checking for false flame, pre-purge, ignition, flame monitoring, and safe shutdown upon flame loss. It uses ionization flame detection with a response time of less than 1 second. This model supersedes the SM592.2 and is designed for heat demand input from a thermostat or controller.

Further details

Applicationgas heating and combination boilers, air heaters, hot air generators, infrared heaters, water heaters, industrial furnaces, drying chambers

Choosing and fitting

When selecting a replacement control box of this type, verify the exact series and type designation, supply voltage, safety and pre-purge times, and flame detection method. Check the pre-purge time (tv), safety time (ts), and wait time (tw) indicated on the unit housing against the requirements of your burner. Ensure the base pattern and flame sensor type correspond before installation. Parts of this type are not interchangeable between series, even within the same brand.

Signs of failure

Typical failures of this kind of control box include lockout due to flame signal not confirmed within the safety time, which requires manual reset. The equipment may fail to start or shut down unexpectedly during operation. Check the flame detector, air pressure switch, and gas pressure switch for proper function, and verify that the control box receives correct signals from these components.

All specifications

Flame detector typeionization
Automatic cyclefull automation
Heat demand inputthermostat or controller

Part numbers

SKU36223321
Additional article246.124.073
ModelSM592N/S
Superseded numberSM592.2