Brahma Control box VM44G 37200755
SKU 37200755
Model VM44G
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 2 s |
| Flame detector type | ionization electrode |
| Protection class (IP) | IP40 |
| Certification | EN 298 |
| Fuel | gas |
| Firing stages | single-stage or two-stage |
| Application | forced draft gas burners |
| Safety standard | EN 298 |
| Air supply | forced draft |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionization |
| Safety feature | non-volatile lockout, manual reset |
| Actuator type | servo drive |
| Operating principle | microprocessor controller |
| Flame monitoring | ionization |
| Operating voltage | 220-240 V |
| Housing type | compact design |
| Microprocessor-based | yes |
| Ambient temperature | -10–60 °C |
| Weight | 400 g |
| Catalogue article numbers | 37200755, 246.124.259 |
| Pre-purge time | 30 s |
| Net weight | 0.4 kg |
354.57 EUR
322.34EUR
in stock · 2
incl. 21% VAT · 266.40 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma VM44G control box (SKU 37200755) is a microprocessor-based controller for automatic ignition, flame monitoring, and safe operation of forced draft gas burners. It operates at 220–240 V, with a safety time of 2 seconds and a pre-purge time of 30 seconds. Flame detection is via ionization electrode, and it supports single-stage or two-stage burner operation. The device is certified to EN 298, has an IP40 protection class, weighs 0.4 kg, and is designed for intermittent duty with a service life of 250,000 cycles under maximum load. It features non-volatile lockout with manual reset and includes a compact housing.
Choosing and fitting
When selecting a replacement control box of this type, ensure the supply voltage, safety time, pre-purge time, and flame detection method match the original unit. The mounting pattern and connector base must be compatible with the burner's wiring. Verify the fuel type (gas) and burner configuration (single-stage or two-stage) to ensure proper operation. Always compare the exact model and part number with the original specification before ordering.
Signs of failure
Common failures of this kind include lockout due to flame detection issues, such as a faulty ionization electrode or contaminated flame sensor. The burner may fail to start or shut down during operation, often indicated by a lockout light. Check the electrode position, wiring, and the control box's fuse or varistor for damage. If the control box locks out and cannot be reset, it may need replacement.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 2 s |
| Flame detector type | ionization electrode |
| Protection class (IP) | IP40 |
| Certification | EN 298 |
| Fuel | gas |
| Firing stages | single-stage or two-stage |
| Application | forced draft gas burners |
| Safety standard | EN 298 |
| Air supply | forced draft |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionization |
| Safety feature | non-volatile lockout, manual reset |
| Actuator type | servo drive |
| Operating principle | microprocessor controller |
| Flame monitoring | ionization |
| Operating voltage | 220-240 V |
| Housing type | compact design |
| Microprocessor-based | yes |
| Ambient temperature | -10–60 °C |
| Weight | 400 g |
| Catalogue article numbers | 37200755, 246.124.259 |
| Pre-purge time | 30 s |
| Net weight | 0.4 kg |
Part numbers
| SKU | 37200755 |
|---|---|
| Additional article | 246.124.259 |
| Model | VM44G |