Honeywell Control box 02431

SKU 02431 Brand Honeywell

Photos

Key specifications

Supply voltage220–240 V
Safety time10 s
Protection class (IP)IP44
Fuelgas or oil
Mounting positionany
Post-ignition time2–5 sec
Weight incl. wiring base0.25 kg
Pre-purge time12 s
Pre-ignition time12 s
Net weight0.25 kg
all specifications (10) ↓
121.57 EUR
110.52EUR
in stock · 38

incl. 21% VAT · 91.34 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell Control box 02431, type designations MZ 770 S, IRD 1010, and UVD 970, is a control box for gas or oil burners. It operates on a supply voltage of 220–240 V and has a safety time of 10 seconds. The pre-purge and pre-ignition times are both 12 seconds, with a post-ignition time of 2–5 seconds. The net weight is 0.25 kg, and it has a protection class of IP44. It can be mounted in any position and fits the Resideo TF832.3.

Further details

Flame Detectorphotoresistor MZ 770 S, infrared-flicker detector IRD 1010, UV solid state sensor UVD 970
Mounting positionany
Power consumptionca. 5 VA
Pre-ignition timeca. 12 sec
Pre-purge timeca. 12 sec
Protection classIP44
Reset time from lockoutca. 90 sec

Choosing and fitting

Control boxes of this type are selected by matching the supply voltage, safety time, and purge/ignition timings to the burner's specifications. The mounting position is flexible, but the wiring base must be compatible with the existing harness. Before ordering, verify the flame detection method (e.g., photoresistor, infrared, or UV) and ensure the control box's protection class meets the installation environment. Physical dimensions and weight should be compared to the original part to ensure a proper fit.

Signs of failure

When control boxes of this kind fail, the burner may fail to start, lock out after the safety time, or shut down intermittently. Common issues include faulty flame detection, which can cause repeated lockouts, or internal relay failures leading to no ignition. Check the flame sensor for contamination or damage, and verify the supply voltage and wiring connections. If the control box resets after a lockout but the problem persists, it may need replacement.

Fits equipment

Resideo TF832.3

All specifications

Supply voltage220–240 V
Safety time10 s
Protection class (IP)IP44
Fuelgas or oil
Mounting positionany
Post-ignition time2–5 sec
Weight incl. wiring base0.25 kg
Pre-purge time12 s
Pre-ignition time12 s
Net weight0.25 kg

Part numbers

SKU02431
Additional article852.124.109
Type designationMZ 770 S
Type designationIRD 1010
Type designationUVD 970