Honeywell Control box 0620920U

SKU 0620920U Brand Honeywell

Photos

Key specifications

Safety time5 s
Flame detector type20
Protection class (IP)IP44
Body materialtransparent, non-flammable plastic
Weight incl. wiring base350 kg
Fuelgas, gas-oil combination
Firing stagestwo-stage
Operating voltage220 / 240 V (-15... +10%)
Mounting positionany
Ambient temperature-20–60 °C
Weight including base350 g
Flame detection methods supportedionization, infrared
Plug-in designplug-in printed circuit boards
Displaycolorful program display
EN 298 classificationbtllxn
Power consumption10 W
Waiting time9 s
Voltage tolerance-15...+10%
Amplifier sensitivity1 µA
Min. current from UV tube or ionisation probe5 µA
Time delay term.6 / term.C10 s
Frequency range50–60 Hz
Air proving switch6
Infrared detector modelIRD 1020
Drive mechanismsynchronous motor with speed reducer
Program cam positions12
Air supplyforced draft
Housing typetransparent, non-flammable plastic removable casing
Pre-purge time24 s
Pre-ignition time8 s
all specifications (30) ↓
459.68 EUR
417.89EUR
in stock · 5

incl. 21% VAT · 345.36 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This is an automatic control box for two-stage, forced-draft burners operating on gas or gas-oil combinations. It runs on 220/240 V (-15...+10%), 50-60 Hz, and draws 10 W. Its timing sequence provides a 5 s safety time, 24 s pre-purge time, and 8 s pre-ignition time, and it supports flame detector cable lengths up to 20 m. The unit uses ionization or infrared flame detection (IRD 1020), and is enclosed in a transparent, non-flammable plastic removable casing rated IP44 for ambient temperatures from -20 to +60 °C.

Further details

Air pressure monitorworking contact 4 A, 230 V
Classified acc. to EN 298BTLLXN
Fuse ratingmax. 10 A rapid, 6 A slow
Infrared flare detectorIRD 1020
Insulation standardIP 44
Mounting attitudeany
Permissable ambient temp.-20° C... +60°C
Reset Button Typebacklit button for fault indication and reset
Serial Fusemax. 10 A rapid, 6 A slow

Fits equipment

Satronic MMI810.1 mod.35

All specifications

Safety time5 s
Flame detector type20
Protection class (IP)IP44
Body materialtransparent, non-flammable plastic
Weight incl. wiring base350 kg
Fuelgas, gas-oil combination
Firing stagestwo-stage
Operating voltage220 / 240 V (-15... +10%)
Mounting positionany
Ambient temperature-20–60 °C
Weight including base350 g
Flame detection methods supportedionization, infrared
Plug-in designplug-in printed circuit boards
Displaycolorful program display
EN 298 classificationbtllxn
Power consumption10 W
Waiting time9 s
Voltage tolerance-15...+10%
Amplifier sensitivity1 µA
Min. current from UV tube or ionisation probe5 µA
Time delay term.6 / term.C10 s
Frequency range50–60 Hz
Air proving switch6
Infrared detector modelIRD 1020
Drive mechanismsynchronous motor with speed reducer
Program cam positions12
Air supplyforced draft
Housing typetransparent, non-flammable plastic removable casing
Pre-purge time24 s
Pre-ignition time8 s

Part numbers

SKU0620920U
Additional article534.412.902
Type designationIRD 1020