{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Honeywell Control box DKG972-N mod. 03 0432003

SKU 0432003 Model DKG972-N mod. 03 Brand Honeywell

Photos

Key specifications

Supply voltage230 V
Protection class (IP)IP40
Operating voltage230 V (-15...+10%)
Consumption12 m3/h
Min. required ionization current (flame level)1 mkA
Sensitivity, operating mode (no flame level)0.7 µA
Sensitivity to ambient light0.4 µA
Max. Ionization current26 µA
Weight175 g
Serial fuse10 A fast, 6 A slow
EN 298 classificationATLLXN
CertificationEN 298:2003, EN 230:2005
Fuelgas
Firing stagestwo-stage
connection_typeplug-in
Safety standardEN 298:2003, EN 230:2005
Built-in displayyes
Replacement guidancefunctionally replaces DKG972
Net weight0.175 kg
all specifications (19) ↓
181.84 EUR
165.31EUR
in stock · 6

incl. 21% VAT · 136.62 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell Control box DKG972-N mod. 03 0432003 is a microprocessor-based control unit for two-stage atmospheric gas burners. It operates at 230 V (-15...+10%) with a consumption of 12 VA. The device requires a minimum ionization current of 1 µA for flame detection, with a sensitivity of 0.7 µA in no-flame mode and 0.4 µA to ambient light. It has a maximum ionization current of 26 µA, weighs 175 g, and is rated IP40. The control box is certified to EN 298:2003 and EN 230:2005, classified as ATLLXN, and includes a built-in display for monitoring and error diagnostics.

Further details

Classification EN298ATLLXN
Ice formation, water exposure and condensationnot allowed
Parasitic capacityProbe – Ground less than 1000 pF
Probe isolationProbe – Ground more than 50 M
Protection classIP 40
Serial fuse10 A fast, 6 A slow
Tested in accordance with the European standardEN 298:2003, as well as all related regulations and directives

Choosing and fitting

Parts of this type are selected by matching the operating voltage, fuel type, burner stage configuration, and safety standard. The control box is plug-in type, so ensure the connector and wiring match the existing harness. Verify the required ionization current and sensitivity parameters align with the flame sensor used. The unit functionally replaces the DKG972 model, but confirm compatibility with the specific burner model and any additional requirements.

Signs of failure

Common failure modes include failure to ignite, intermittent flame loss, or lockout without restart. The built-in display may show error codes indicating the cause. Check the ionization electrode for proper positioning and cleanliness, and verify the supply voltage and fuse ratings. If the unit fails to respond, test the flame sensor circuit and replace the control box if necessary.

All specifications

Supply voltage230 V
Protection class (IP)IP40
Operating voltage230 V (-15...+10%)
Consumption12 m3/h
Min. required ionization current (flame level)1 mkA
Sensitivity, operating mode (no flame level)0.7 µA
Sensitivity to ambient light0.4 µA
Max. Ionization current26 µA
Weight175 g
Serial fuse10 A fast, 6 A slow
EN 298 classificationATLLXN
CertificationEN 298:2003, EN 230:2005
Fuelgas
Firing stagestwo-stage
connection_typeplug-in
Safety standardEN 298:2003, EN 230:2005
Built-in displayyes
Replacement guidancefunctionally replaces DKG972
Net weight0.175 kg

Part numbers

SKU0432003
Additional article852.124.212
ModelDKG972-N mod. 03