Honeywell Control box DKG972-N mod. 05 0432005
SKU 0432005
Model DKG972-N mod. 05
Brand Honeywell
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Protection class (IP) | IP40 |
| Body material | fire-resistant plastic |
| Operating voltage | 230.0 V |
| Consumption | 12 m3/h |
| Sensitivity, operating mode (no flame level) | 0.7 µA |
| Sensitivity to ambient light | 0.4 µA |
| Max. Ionization current | 26 µA |
| Voltage tolerance | -15...+10% |
| Fuel | gas |
| Firing stages | two-stage |
| Plug-in design | plug-in |
| Microprocessor-based | yes |
| Flame arrester | flame arrestor machine |
| Built-in display | visual information system |
| Weight | 175 g |
| Serial fuse | 10 A fast, 6 A slow |
| Min. required ionization current (flame level) | 1 mkA |
| Certification | EN 298:2003, EN 230:2005 |
| EN 298 classification | atllxn |
| Ice formation, water exposure and condensation | not allowed |
211.06 EUR
191.87EUR
in stock · 25
incl. 21% VAT · 158.57 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This microprocessor-based control box is intended for two-stage atmospheric gas burners and features a plug-in design for straightforward installation. It operates at 230 V with a voltage tolerance of -15...+10% and is housed in a fire-resistant plastic enclosure with protection class IP40. The unit is certified according to EN 298:2003 and EN 230:2005 and holds EN 298 classification atllxn. A built-in visual information system with LEDs provides continuous monitoring of the startup sequence and indicates possible blocking reasons. For flame control, it requires a minimum ionization current of 1 µA, has an ambient light sensitivity of 0.4 µA, and a maximum ionization current of 26 µA. The control box weighs 175 g and uses a 10 A fast and 6 A slow serial fuse.
Further details
| Classification EN298 | ATLLXN |
|---|---|
| Error Memory | latest causes of errors stored and restored after voltage drop |
| Ice formation, water exposure and condensation | not allowed |
| Parasitic capacity | Probe – Ground less than 1000 pF |
| Probe isolation | Probe – Ground more than 50 M |
| Protection class | IP 40 |
| Serial fuse | 10 A fast, 6 A slow |
| Tested in accordance with the European standard | EN 298:2003, as well as all related regulations and directives |
Fits equipment
Honeywell two-stage atmospheric burners
All specifications
| Supply voltage | 230 V |
|---|---|
| Protection class (IP) | IP40 |
| Body material | fire-resistant plastic |
| Operating voltage | 230.0 V |
| Consumption | 12 m3/h |
| Sensitivity, operating mode (no flame level) | 0.7 µA |
| Sensitivity to ambient light | 0.4 µA |
| Max. Ionization current | 26 µA |
| Voltage tolerance | -15...+10% |
| Fuel | gas |
| Firing stages | two-stage |
| Plug-in design | plug-in |
| Microprocessor-based | yes |
| Flame arrester | flame arrestor machine |
| Built-in display | visual information system |
| Weight | 175 g |
| Serial fuse | 10 A fast, 6 A slow |
| Min. required ionization current (flame level) | 1 mkA |
| Certification | EN 298:2003, EN 230:2005 |
| EN 298 classification | atllxn |
| Ice formation, water exposure and condensation | not allowed |
Part numbers
| SKU | 0432005 |
|---|---|
| Additional article | 852.124.205 |
| Model | DKG972-N mod. 05 |