Honeywell Control box DKG972-N mod. 21 0432021
SKU 0432021
Model DKG972-N mod. 21
Brand Honeywell
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Protection class (IP) | IP40 |
| Body material | fire-resistant plastic |
| Consumption | 12 m3/h |
| Weight | 175 g |
| Cycle type | two-stage atmospheric burners |
| Sensitivity, operating mode (no flame level) | 0.7 µA |
| Sensitivity to ambient light | 0.4 µA |
| Max. Ionization current | 26 µA |
| EN 298 classification | atllxn |
| Min. required ionization current (flame level) | 1 mkA |
| Safety standard | EN 298:2003, EN 230:2005 |
| Microprocessor-based | Yes |
| Application | direct-acting air heaters (DIN 4794) |
| Application type | two-stage atmospheric burners |
| Firing stages | two-stage |
| Serial fuse | 10 A fast, 6 A slow |
| Plug-in design | Yes |
| Built-in display | Yes |
| Error memory | Yes |
| Replacement guidance | functionally replaces DKG972 |
| Flame arrester | Yes |
| Flame relay output | Yes |
| LED indicators | Yes |
| Net weight | 0.175 kg |
182.64 EUR
166.04EUR
in stock · 50
incl. 21% VAT · 137.22 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Honeywell DKG972-N mod. 21 control box (SKU 0432021) is a microprocessor-based unit for two-stage atmospheric burners. Operating at 230 V with a consumption of 12 m3/h, it provides flame supervision via ionization current with a sensitivity of 0.7 µA in no-flame mode, a sensitivity to ambient light of 0.4 µA, and a maximum ionization current of 26 µA. The minimum required ionization current for flame level is 1 mkA. The unit includes a built-in display, LED indicators, error memory, flame relay output, and flame arrester. Its housing is made of fire-resistant plastic, rated IP40, and weighs 175 g. It complies with EN 298:2003 and EN 230:2005, classification ATLLXN, and functionally replaces the earlier DKG972 control box.
Further details
| Application | atmospheric gas burners of two-stage type, direct-acting air heaters (DIN 4794) |
|---|---|
| Classification EN298 | ATLLXN |
| Environmental restriction | ice formation, water exposure and condensation not allowed |
| Ice formation, water exposure and condensation | not allowed |
| Parasitic capacity | Probe – Ground less than 1000 pF |
| Probe isolation | Probe – Ground more than 50 M |
| Protection class | IP 40 |
| Tested in accordance with the European standard | EN 298:2003, as well as all related regulations and directives |
Fits equipment
Honeywell DKG972
All specifications
| Supply voltage | 230 V |
|---|---|
| Protection class (IP) | IP40 |
| Body material | fire-resistant plastic |
| Consumption | 12 m3/h |
| Weight | 175 g |
| Cycle type | two-stage atmospheric burners |
| Sensitivity, operating mode (no flame level) | 0.7 µA |
| Sensitivity to ambient light | 0.4 µA |
| Max. Ionization current | 26 µA |
| EN 298 classification | atllxn |
| Min. required ionization current (flame level) | 1 mkA |
| Safety standard | EN 298:2003, EN 230:2005 |
| Microprocessor-based | Yes |
| Application | direct-acting air heaters (DIN 4794) |
| Application type | two-stage atmospheric burners |
| Firing stages | two-stage |
| Serial fuse | 10 A fast, 6 A slow |
| Plug-in design | Yes |
| Built-in display | Yes |
| Error memory | Yes |
| Replacement guidance | functionally replaces DKG972 |
| Flame arrester | Yes |
| Flame relay output | Yes |
| LED indicators | Yes |
| Net weight | 0.175 kg |
Part numbers
| SKU | 0432021 |
|---|---|
| Additional article | 852.124.134 |
| Model | DKG972-N mod. 21 |