Honeywell Control box DKG972-N mod. 21 0432021

SKU 0432021 Model DKG972-N mod. 21 Brand Honeywell

Photos

Key specifications

Supply voltage230 V
Protection class (IP)IP40
Body materialfire-resistant plastic
Consumption12 m3/h
Weight175 g
Cycle typetwo-stage atmospheric burners
Sensitivity, operating mode (no flame level)0.7 µA
Sensitivity to ambient light0.4 µA
Max. Ionization current26 µA
EN 298 classificationatllxn
Min. required ionization current (flame level)1 mkA
Safety standardEN 298:2003, EN 230:2005
Microprocessor-basedYes
Applicationdirect-acting air heaters (DIN 4794)
Application typetwo-stage atmospheric burners
Firing stagestwo-stage
Serial fuse10 A fast, 6 A slow
Plug-in designYes
Built-in displayYes
Error memoryYes
Replacement guidancefunctionally replaces DKG972
Flame arresterYes
Flame relay outputYes
LED indicatorsYes
Net weight0.175 kg
all specifications (25) ↓
182.64 EUR
166.04EUR
in stock · 50

incl. 21% VAT · 137.22 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Honeywell DKG972-N mod. 21 control box (SKU 0432021) is a microprocessor-based unit for two-stage atmospheric burners. Operating at 230 V with a consumption of 12 m3/h, it provides flame supervision via ionization current with a sensitivity of 0.7 µA in no-flame mode, a sensitivity to ambient light of 0.4 µA, and a maximum ionization current of 26 µA. The minimum required ionization current for flame level is 1 mkA. The unit includes a built-in display, LED indicators, error memory, flame relay output, and flame arrester. Its housing is made of fire-resistant plastic, rated IP40, and weighs 175 g. It complies with EN 298:2003 and EN 230:2005, classification ATLLXN, and functionally replaces the earlier DKG972 control box.

Further details

Applicationatmospheric gas burners of two-stage type, direct-acting air heaters (DIN 4794)
Classification EN298ATLLXN
Environmental restrictionice formation, water exposure and condensation not allowed
Ice formation, water exposure and condensationnot allowed
Parasitic capacityProbe – Ground less than 1000 pF
Probe isolationProbe – Ground more than 50 M
Protection classIP 40
Tested in accordance with the European standardEN 298:2003, as well as all related regulations and directives

Fits equipment

Honeywell DKG972

All specifications

Supply voltage230 V
Protection class (IP)IP40
Body materialfire-resistant plastic
Consumption12 m3/h
Weight175 g
Cycle typetwo-stage atmospheric burners
Sensitivity, operating mode (no flame level)0.7 µA
Sensitivity to ambient light0.4 µA
Max. Ionization current26 µA
EN 298 classificationatllxn
Min. required ionization current (flame level)1 mkA
Safety standardEN 298:2003, EN 230:2005
Microprocessor-basedYes
Applicationdirect-acting air heaters (DIN 4794)
Application typetwo-stage atmospheric burners
Firing stagestwo-stage
Serial fuse10 A fast, 6 A slow
Plug-in designYes
Built-in displayYes
Error memoryYes
Replacement guidancefunctionally replaces DKG972
Flame arresterYes
Flame relay outputYes
LED indicatorsYes
Net weight0.175 kg

Part numbers

SKU0432021
Additional article852.124.134
ModelDKG972-N mod. 21