Honeywell Control unit DVI980-N mod. 02 0490602U
SKU 0490602U
Model DVI980-N mod. 02
Brand Honeywell
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Protection class (IP) | IP40 |
| Spark energy | 10 mJ |
| Ignition transformer voltage | 20 kV |
| Sensitivity | 1.0 µA |
| Min. required ion. current | 1.5 µA |
| Sensitivity for stray light | 0.4 µA |
| Weight incl. wiring base | 190 kg |
| Installation position | any |
| Mounting position | any |
| Net weight | 0.19 kg |
170.76 EUR
155.24EUR
in stock · 4
incl. 21% VAT · 128.30 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell DVI980-N mod. 02 control box is a control unit designed for 1-stage forced draught and atmospheric gas burners, capable of operating with DC valves. It supports flame detection via an ionization probe, infrared flicker detector (IRD 1020.1), or UV flame sensor (UVD 971). The unit operates at a supply voltage of 220–240 V, provides ignition spark energy of 10 mJ at 20 kV, and has a sensitivity of 1.0 µA with a minimum required ion current of 1.5 µA. It weighs 0.19 kg net (190 g including wiring base) and has an IP40 protection class. The control box can be installed in any position.
Further details
| Air proving switch | 1 working contact |
|---|---|
| Cable length | < 3 m |
| Flame Detector | ionisation probe, infrared flicker detector 1020.1, uv flame sensor uvd 971 |
| Flame detectors IRD 1020.1 | end-on viewing |
| Flame signal output | Optocoupler max 70V DC/100mA |
| Ignition frequency | up to 40 Hz |
| Mounting position | any |
| Power consumption | ca. 12 VA |
| Protection class | IP 40 |
| STB Safety temperature delimiter | 1 working contact |
| Stray capacity | Probe - earth less than 1000 pF |
| Total load | max. 6 A during 0,5 sec |
| UVD 971 | end-on viewing |
Choosing and fitting
When selecting a control box of this type, ensure the supply voltage matches the burner's electrical system (e.g., 220–240 V). Verify the flame detector type (ionization probe, IR, or UV) is compatible with the control box's input specifications. Check the ignition voltage and spark energy requirements of the burner to match the control box's output. The mounting position is flexible, but the wiring base must be correctly connected according to the manufacturer's diagram. Always compare the control box's sensitivity and ion current thresholds with the burner's flame characteristics.
Signs of failure
Common failure modes for this type of control box include failure to ignite, intermittent flame loss, or no response to flame signals. Symptoms may include the burner not starting, locking out after repeated ignition attempts, or shutting down during operation. Check the ignition transformer, flame detector, and wiring connections for faults. Verify that the ion current or UV/IR signal is within the required range, and inspect for loose connections or damaged components.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Protection class (IP) | IP40 |
| Spark energy | 10 mJ |
| Ignition transformer voltage | 20 kV |
| Sensitivity | 1.0 µA |
| Min. required ion. current | 1.5 µA |
| Sensitivity for stray light | 0.4 µA |
| Weight incl. wiring base | 190 kg |
| Installation position | any |
| Mounting position | any |
| Net weight | 0.19 kg |
Part numbers
| SKU | 0490602U |
|---|---|
| Additional article | 852.124.213 |
| Model | DVI980-N mod. 02 |