Honeywell Control box DVI980-N mod. 04 0490604
SKU 0490604
Model DVI980-N mod. 04
Brand Honeywell
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Protection class (IP) | IP40 |
| Spark energy | 10 mJ |
| Ignition transformer voltage | 20 kV |
| Sensitivity | 1.0 µA |
| Min. required ion. current | 1.5 µA |
| Sensitivity for stray light | 0.4 µA |
| Weight incl. wiring base | 190 kg |
| Fuel | gas |
| Firing stages | 1-stage |
| Installation position | any |
| Mounting position | any |
| Net weight | 0.19 kg |
198.76 EUR
180.69EUR
in stock · 10
incl. 21% VAT · 149.33 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell Control box DVI980-N mod. 04 (SKU 0490604) is a control box for 1-stage forced draught and atmospheric gas burners. It operates on a supply voltage of 220–240 V and provides an ignition transformer voltage of 20 kV with a spark energy of 10 mJ. The device has a sensitivity of 1.0 µA, a minimum required ion current of 1.5 µA, and a sensitivity for stray light of 0.4 µA. It weighs 0.19 kg net (190 g including wiring base) and has a protection class of IP40. The control box can be installed in any position and is suitable for gas fuel.
Further details
| Air proving switch | 1 working contact |
|---|---|
| Cable length | < 3 m |
| Certification | approved and certified according to the applicable european standards and regulations |
| Flame Detector | ionisation probe, infrared flicker detector 1020.1, uv flame sensor uvd 971 |
| Flame detectors IRD 1020.1 | end-on viewing |
| Flame signal output | Optocoupler max 70V DC/100mA |
| Ignition frequency | up to 40 Hz |
| Mounting position | any |
| Power consumption | ca. 12 VA |
| Protection class | IP 40 |
| STB Safety temperature delimiter | 1 working contact |
| Stray capacity | Probe - earth less than 1000 pF |
| Total load | max. 6 A during 0,5 sec |
| UVD 971 | end-on viewing |
Choosing and fitting
Control boxes of this type are selected based on the burner's fuel type, number of stages, and required flame detection method. Ensure the supply voltage matches the burner's electrical system, and verify that the control box's sensitivity parameters are compatible with the flame detector used. The mounting position is flexible, but the wiring base must be correctly connected. Before ordering, compare the control box's specifications with the burner's requirements, including the ignition voltage and spark energy.
Signs of failure
When control boxes of this kind fail, the burner may not start or may shut down during operation. Common issues include failure to ignite, intermittent flame loss, or no response to flame signals. Check the ignition transformer, flame detector, and wiring connections for faults. If the control box is suspected, test its output signals and replace it if necessary.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Protection class (IP) | IP40 |
| Spark energy | 10 mJ |
| Ignition transformer voltage | 20 kV |
| Sensitivity | 1.0 µA |
| Min. required ion. current | 1.5 µA |
| Sensitivity for stray light | 0.4 µA |
| Weight incl. wiring base | 190 kg |
| Fuel | gas |
| Firing stages | 1-stage |
| Installation position | any |
| Mounting position | any |
| Net weight | 0.19 kg |
Part numbers
| SKU | 0490604 |
|---|---|
| Additional article | 852.124.060 |
| Model | DVI980-N mod. 04 |