Honeywell Control box MMG811.1 mod.63 0640420
SKU 0640420
Model MMG811.1 mod.63
Brand Honeywell
Photos
no photo yet
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 3 s |
| Flame detector type | 20 |
| Protection class (IP) | IP44 |
| Flame detection methods supported | Ionisation, UV, IR |
| Certification | Approved as per EN 298 |
| Fuel | Oil/Gas |
| Firing stages | 2-stage |
| Burner capacity | Any nominal rating |
| Air supply | Forced draught |
| Mounting position | Any |
| Ambient temperature | -20–60 °C |
| Weight including base | 350 g |
| EN 298 classification | BTLLXN |
| Time delay term.6 / term.C | 6 s |
| Amplifier sensitivity | 1 µA |
| Min. current from UV tube or ionisation probe | 5 µA |
| Infrared detector model | IRD 1020 |
| Waiting time | 6 s |
| Voltage tolerance | -15... +10% |
| Frequency range | 50–60 Hz |
| Power consumption | 10 W |
| Air proving switch | 5 |
| Reset delay | none |
| Fuse rating | max. 10 A rapid, 6 A slow |
| Weight incl. wiring base | 350 kg |
| Pre-purge time | 55 s |
| Pre-ignition time | 5.5 s |
765.46 EUR
695.87EUR
in stock · 2
incl. 21% VAT · 575.10 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This Honeywell control box is designed for two-stage forced draught oil/gas burners and is approved as per EN 298. It operates on a supply voltage of 220–240 V AC at 50–60 Hz, with a power consumption of 10 W. Its timing schedule includes a 6 s waiting time, a 55 s pre-purge time, a 5.5 s pre-ignition time, and a 3 s safety time. It supports ionisation probes, UV sensors, and the IRD 1020 infrared detector. For ionisation or UV sensing, the minimum required current is 5 µA. The control box is rated IP44, may be mounted in any position, and is certified for ambient temperatures between -20 and +60 °C.
Further details
| AC frequency variations | result in proportional timing deviations |
|---|---|
| Classified acc. to EN 298 | BTLLXN |
| Infrared flare detector | IRD 1020 |
| Insulation standard | IP 44 |
| Mounting attitude | any |
| Permissable ambient temp. | -20° C... +60°C |
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Safety time | 3 s |
| Flame detector type | 20 |
| Protection class (IP) | IP44 |
| Flame detection methods supported | Ionisation, UV, IR |
| Certification | Approved as per EN 298 |
| Fuel | Oil/Gas |
| Firing stages | 2-stage |
| Burner capacity | Any nominal rating |
| Air supply | Forced draught |
| Mounting position | Any |
| Ambient temperature | -20–60 °C |
| Weight including base | 350 g |
| EN 298 classification | BTLLXN |
| Time delay term.6 / term.C | 6 s |
| Amplifier sensitivity | 1 µA |
| Min. current from UV tube or ionisation probe | 5 µA |
| Infrared detector model | IRD 1020 |
| Waiting time | 6 s |
| Voltage tolerance | -15... +10% |
| Frequency range | 50–60 Hz |
| Power consumption | 10 W |
| Air proving switch | 5 |
| Reset delay | none |
| Fuse rating | max. 10 A rapid, 6 A slow |
| Weight incl. wiring base | 350 kg |
| Pre-purge time | 55 s |
| Pre-ignition time | 5.5 s |
Part numbers
| SKU | 0640420 |
|---|---|
| Additional article | 852.124.069 |
| Model | MMG811.1 mod.63 |