{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Honeywell Gas burner safety control box MMI810.1 mod.43 0622520

SKU 0622520 Model MMI810.1 mod.43 Brand Honeywell

Photos

Key specifications

Supply voltage220–240 V
Safety time3 s
Flame detector typeionization probe, infrared flicker detector
Protection class (IP)IP44
Body materialnon-flammable plastic
Waiting time9 s
Air proving switch6.0 s
Time delay term.6 / term.C10 s
Power consumption10 W
Amplifier sensitivity1 µA
Min. current from UV tube or ionisation probe5 µA
Weight incl. wiring base350 kg
Fuelgas or oil
Firing stagestwo-stage
Pre-purge time40 s
Pre-ignition time3 s
Net weight0.35 kg
all specifications (17) ↓
461.20 EUR
419.27EUR
in stock · 1

incl. 21% VAT · 346.50 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Honeywell MMI810.1 mod.43 is a gas burner safety control box for two-stage forced draught and combi oil/gas burners. It supports ionization probe or infrared flicker detector as flame detectors. The device operates on 220–240 V supply voltage, consumes 10 W, and has a waiting time of 9 s, air proving switch reaction time of 6.0 s, pre-purge time of 40 s, pre-ignition time of 3 s, safety time of 3 s, and time delay between terminals 6 and C of 10 s. It has an amplifier sensitivity of 1 µA and requires a minimum current of 5 µA from the flame detector. The control box weighs 0.35 kg net, has IP44 protection, and is housed in a non-flammable plastic casing.

Further details

Air pressure monitorworking contact 4 A, 230 V
Classified acc. to EN 298BTLLXN
Flame detector cablemax. 20 m cable length
Fuse ratingmax. 10 A rapid, 6 A slow
Infrared flare detectorIRD 1020
Insulation standardIP 44
Mounting attitudeany
Permissable ambient temp.-20° C... +60°C

Choosing and fitting

When selecting a replacement control box of this type, ensure the supply voltage, flame detector type, and program sequence match the burner's requirements. Verify the waiting time, pre-purge time, safety time, and other timing parameters align with the burner's specifications. The control box must be compatible with the burner's wiring and mounting configuration. Check the physical dimensions and mounting holes to ensure a proper fit.

Signs of failure

Common failures of this kind of control box include failure to start, intermittent lockouts, or no ignition. Symptoms may include the burner not responding to the thermostat, repeated resetting, or the fault indicator lighting up. Check the flame detector signal, wiring connections, and the control box's internal fuses. If the control box is faulty, it may need to be replaced.

All specifications

Supply voltage220–240 V
Safety time3 s
Flame detector typeionization probe, infrared flicker detector
Protection class (IP)IP44
Body materialnon-flammable plastic
Waiting time9 s
Air proving switch6.0 s
Time delay term.6 / term.C10 s
Power consumption10 W
Amplifier sensitivity1 µA
Min. current from UV tube or ionisation probe5 µA
Weight incl. wiring base350 kg
Fuelgas or oil
Firing stagestwo-stage
Pre-purge time40 s
Pre-ignition time3 s
Net weight0.35 kg

Part numbers

SKU0622520
Additional article852.124.076
ModelMMI810.1 mod.43