| Supply voltage | 230–240 V |
|---|---|
| Fuel | gas |
| connection_type | Molex 3001 multi-edge connector |
| Application | dbi or ip |
| Service life under maximum load | 250000 |
| Connector type | Molex 3001 multi-edge connector |
| Safety valve operator cycles | 500000 cycles |
| Blocking operations | 6000 cycles |
| Sparking hours | 1000 hours |
| Compatible gas valves | VR4600 series |
| Gas regulator compatibility | VR4600 series |
| Reset/alarm mode | integral or remote |
| Electromagnetic filter | yes |
439.23 EUR
399.30EUR
in stock · 2
incl. 21% VAT · 330.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell S4564BF1014U is a gas boiler control unit designed for periodic ignition systems of pilot burners. It operates on a supply voltage of 230–240 V and is compatible with gas valves of the VR4600 series. The unit supports both DBI and IP ignition applications and features an electromagnetic filter. It connects via a Molex 3001 multi-edge connector and has a service life of 250,000 cycles under maximum load, with 500,000 safety valve operator cycles, 6,000 blocking operations, and 1,000 hours of sparking. Reset and alarm modes can be integral or remote.
Choosing and fitting
When selecting a control unit of this type, ensure the supply voltage matches the system (e.g., 230–240 V) and that the gas valve series is compatible (e.g., VR4600). The connection type must correspond to the existing wiring, such as a Molex 3001 multi-edge connector. Verify the application type (DBI or IP) and the required reset/alarm configuration (integral or remote). Installation orientation can vary within ±90° from vertical, and the unit should be mounted to allow proper electrical connections.
Signs of failure
Typical failures of such control units include failure to ignite, intermittent operation, or complete shutdown. Symptoms may include the alarm indicator lighting up, the gas valve not opening, or no spark generation. Check the supply voltage, connections, and the condition of the flame detection rod. If the unit has exceeded its rated cycles (e.g., 250,000 under maximum load), it may need replacement.
All specifications
| Supply voltage | 230–240 V |
|---|---|
| Fuel | gas |
| connection_type | Molex 3001 multi-edge connector |
| Application | dbi or ip |
| Service life under maximum load | 250000 |
| Connector type | Molex 3001 multi-edge connector |
| Safety valve operator cycles | 500000 cycles |
| Blocking operations | 6000 cycles |
| Sparking hours | 1000 hours |
| Compatible gas valves | VR4600 series |
| Gas regulator compatibility | VR4600 series |
| Reset/alarm mode | integral or remote |
| Electromagnetic filter | yes |
Part numbers
| SKU | S4564BF1014U |
|---|---|
| Additional article | 534.412.153 |