{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Honeywell Control box S4966V2029

SKU S4966V2029 Brand Honeywell

Photos

Key specifications

Supply voltage230 V
Maximum humidity90
Applicationgas domestic heating installations
Application typepre-mixing processes
Power consumption18 W
Frequency range47–65 Hz
Fuelgas
Ignition device floating potentialyes
all specifications (8) ↓
549.04 EUR
499.13EUR
in stock · 24

incl. 21% VAT · 412.50 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell S4966V2029 control box is designed for gas domestic heating installations, specifically for pre-mixing processes. It operates with a supply voltage of 230 V and a frequency range of 47–65 Hz, with a maximum power consumption of 18 W. The device supports a maximum relative humidity of 90% and features a floating ignition potential. It is compatible with VK41, VK, and VR series gas regulators.

Further details

Ambient temperatureOperating temperature: -10° - 60°C
Voltage230 V AC - 47 - 65 Hz < 3 W standby, 18 W maximum power consumption

Choosing and fitting

Parts of this type are selected by matching the supply voltage, frequency range, and power consumption to the system's specifications. The control box must be compatible with the gas regulator series (e.g., VK41, VK, VR) and the ignition system type. Installation involves connecting the control box to the electrical circuit and ensuring proper wiring for ignition and flame sensing. Always verify the operating temperature range and humidity limits before installation.

Signs of failure

When control boxes of this kind fail, common symptoms include ignition failure, flame loss during operation, or erratic burner behavior. The equipment may fail to start, shut down unexpectedly, or display error codes. Check the power supply, wiring connections, and the flame sensing electrode for faults. Also, inspect the control box for signs of overheating or moisture damage.

All specifications

Supply voltage230 V
Maximum humidity90
Applicationgas domestic heating installations
Application typepre-mixing processes
Power consumption18 W
Frequency range47–65 Hz
Fuelgas
Ignition device floating potentialyes

Part numbers

Additional article534.412.906
SKUS4966V2029
Additional article534.412.911
OEM equivalentVK41
OEM equivalentVK
OEM equivalentVR