Honeywell Gas boiler control unit S4565C3116B
SKU S4565C3116B
Brand Honeywell
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Reset method | button or power interruption |
| LPG valve support | yes |
| TC test period tP | performed before pre-purge |
| Extended ignition time | addable after flame established |
| Restart behavior | repeats starting sequence with pre-purging |
| Auxiliary fan | yes |
| Fuel | gas |
| Application | dbi or ip |
| Safety standard | EN 298, EN 60730-1 |
| Safety feature | manual reset lockout |
| Ignition type | direct or pilot ignition |
| Reset wait time | 15 s |
| Connector on top | yes |
| Compatible gas valves | vk41 series gas regulators |
| Flame sensor | flame sensor rod |
| Reset button type | own/external reset button |
| Airflow control relay | present |
| Supported ignition systems | dbi and ip |
| Controlled components | main and pilot burners |
| EN 298 compliance | yes |
| Gas regulator compatibility | vk41 series gas regulators |
| Ignition transformer voltage | built-in or external |
279.51 EUR
254.10EUR
in stock · 1
incl. 21% VAT · 210.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is a gas boiler control unit from Honeywell, catalog number S4565C3116B, belonging to the category of control boxes. It operates on a supply voltage of 220–240 V and is designed for gas-fired equipment with either direct burner ignition (dbi) or pilot burner ignition (ip). The unit conforms to EN 298 and EN 60730-1 and features a manual reset lockout. It performs a test period (tp) before pre-purge and supports flame detection via a flame sensor rod. It is compatible with VK41 series gas regulators and includes a connector on top for simplified wiring. The reset wait time between attempts is 15 seconds, and reset can be done by button or power interruption.
Further details
| Airflow control | relay detects airflow and starts fan |
|---|---|
| Integrated Protection | all burner protection functions are integrated into a reliable system |
| Standby behavior | remains in standby mode with the fan running |
Choosing and fitting
When selecting a replacement control box of this type, check the supply voltage and ignition system type (direct spark or pilot burner). Variants with suffix C include an auxiliary fan, so confirm that the replacement matches the required fan support. The unit mounts onto the gas regulator via a connector on the top and can be oriented within 90° in any direction from the vertical. Ensure the wiring to the gas valve, ignition transformer, and flame sensor matches the original layout.
Fits equipment
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Reset method | button or power interruption |
| LPG valve support | yes |
| TC test period tP | performed before pre-purge |
| Extended ignition time | addable after flame established |
| Restart behavior | repeats starting sequence with pre-purging |
| Auxiliary fan | yes |
| Fuel | gas |
| Application | dbi or ip |
| Safety standard | EN 298, EN 60730-1 |
| Safety feature | manual reset lockout |
| Ignition type | direct or pilot ignition |
| Reset wait time | 15 s |
| Connector on top | yes |
| Compatible gas valves | vk41 series gas regulators |
| Flame sensor | flame sensor rod |
| Reset button type | own/external reset button |
| Airflow control relay | present |
| Supported ignition systems | dbi and ip |
| Controlled components | main and pilot burners |
| EN 298 compliance | yes |
| Gas regulator compatibility | vk41 series gas regulators |
| Ignition transformer voltage | built-in or external |
Part numbers
| SKU | S4565C3116B |
|---|---|
| Additional article | 534.412.061 |