Honeywell Gas boiler control unit S4565R1055U
SKU S4565R1055U
Model S4565R1055
Brand Honeywell
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | ionisation |
| connection_type | connector on top |
| Safety standard | EN 60730-1 |
| Connector on top | yes |
| LPG valve support | yes |
| Model variant | R |
| Fuel | gas |
| Extended ignition time | yes |
| Restart behavior | repeats starting sequence with pre-purging |
| Airflow control relay | yes |
| Supported ignition systems | DBI or IP |
| Integrated protection | yes |
| EN 298 compliance | EN 60335 |
279.51 EUR
254.10EUR
in stock · 1
incl. 21% VAT · 210.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Control unit for gas burners and boilers, type VK41, from Honeywell. It operates on 220–240 V and uses ionisation flame detection. The unit has a connector on top and supports LPG valves, extended ignition time, an airflow control relay, and integrated protection. It is designed for DBI or IP ignition systems; variant R denotes an atmospheric system with spark ignition. The unit fits Honeywell VK41 series and complies with EN 60730-1 and EN 60335.
Further details
| Airflow Control Relay | detects the absence of airflow and starts the fan |
|---|---|
| Airflow control | relay detects absence of airflow and starts fan |
| Extended Ignition Time | a preset extended ignition time can be added |
| Restart Behavior | repeats the starting sequence with pre-purging |
| Supported Ignition Systems | spark ignition of the burner (dbi) and systems with pilot burner (ip) |
Choosing and fitting
Control units of this type are chosen according to the ignition system (DBI or IP) and the gas regulator series; they connect directly via the top-mounted connector. Mounting allows orientation within 90° in any direction from the vertical position of the actuator. Verify the supply voltage and the specific VK41 series variant before fitting.
Signs of failure
When a control unit of this type fails to ignite the burner within the safe ignition time, it locks out. If the flame goes out during normal operation, the unit repeats the starting sequence with pre-purging. If the airflow control relay detects insufficient airflow during pre-purge, the unit stays in standby with the fan running. Lockout can be cleared by pressing the reset button or interrupting the power supply; leave at least 15 seconds before attempting a second reset.
Fits equipment
Honeywell VK41 series
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | ionisation |
| connection_type | connector on top |
| Safety standard | EN 60730-1 |
| Connector on top | yes |
| LPG valve support | yes |
| Model variant | R |
| Fuel | gas |
| Extended ignition time | yes |
| Restart behavior | repeats starting sequence with pre-purging |
| Airflow control relay | yes |
| Supported ignition systems | DBI or IP |
| Integrated protection | yes |
| EN 298 compliance | EN 60335 |
Part numbers
| SKU | S4565R1055U |
|---|---|
| Additional article | 534.412.062 |
| Model | S4565R1055 |
| Type designation | VK41 |