Honeywell Gas boiler control unit S4565R1055U

SKU S4565R1055U Model S4565R1055 Brand Honeywell

Photos

Key specifications

Supply voltage220–240 V
Flame detector typeionisation
connection_typeconnector on top
Safety standardEN 60730-1
Connector on topyes
LPG valve supportyes
Model variantR
Fuelgas
Extended ignition timeyes
Restart behaviorrepeats starting sequence with pre-purging
Airflow control relayyes
Supported ignition systemsDBI or IP
Integrated protectionyes
EN 298 complianceEN 60335
all specifications (14) ↓
279.51 EUR
254.10EUR
in stock · 1

incl. 21% VAT · 210.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Control unit for gas burners and boilers, type VK41, from Honeywell. It operates on 220–240 V and uses ionisation flame detection. The unit has a connector on top and supports LPG valves, extended ignition time, an airflow control relay, and integrated protection. It is designed for DBI or IP ignition systems; variant R denotes an atmospheric system with spark ignition. The unit fits Honeywell VK41 series and complies with EN 60730-1 and EN 60335.

Further details

Airflow Control Relaydetects the absence of airflow and starts the fan
Airflow controlrelay detects absence of airflow and starts fan
Extended Ignition Timea preset extended ignition time can be added
Restart Behaviorrepeats the starting sequence with pre-purging
Supported Ignition Systemsspark ignition of the burner (dbi) and systems with pilot burner (ip)

Choosing and fitting

Control units of this type are chosen according to the ignition system (DBI or IP) and the gas regulator series; they connect directly via the top-mounted connector. Mounting allows orientation within 90° in any direction from the vertical position of the actuator. Verify the supply voltage and the specific VK41 series variant before fitting.

Signs of failure

When a control unit of this type fails to ignite the burner within the safe ignition time, it locks out. If the flame goes out during normal operation, the unit repeats the starting sequence with pre-purging. If the airflow control relay detects insufficient airflow during pre-purge, the unit stays in standby with the fan running. Lockout can be cleared by pressing the reset button or interrupting the power supply; leave at least 15 seconds before attempting a second reset.

Fits equipment

Honeywell VK41 series

All specifications

Supply voltage220–240 V
Flame detector typeionisation
connection_typeconnector on top
Safety standardEN 60730-1
Connector on topyes
LPG valve supportyes
Model variantR
Fuelgas
Extended ignition timeyes
Restart behaviorrepeats starting sequence with pre-purging
Airflow control relayyes
Supported ignition systemsDBI or IP
Integrated protectionyes
EN 298 complianceEN 60335

Part numbers

SKUS4565R1055U
Additional article534.412.062
ModelS4565R1055
Type designationVK41