Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Protection class (IP) | IP40 |
| Storage temperature | -15–40 °C |
| Weight | 0.485 g |
| TC test period tP | 100–600 s |
| Air pressure switch verification | external pressure switch |
| Terminal type | screw terminals |
| Terminal cross-section | 2.5 mm2 |
| Switching current | max. 5 |
| Housing material | impact-resistant plastic |
| Gas type | dependent on external pressure switch |
| Cable gland | M16 plastic cable glands |
| Knock-out holes | 5 |
| Net weight | 0.485 kg |
1597.20 EUR
1452.00EUR
in stock · 1
incl. 21% VAT · 1200.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Kromschroder tightness control 84765820 is a control box used for tightness testing of gas safety valves before every controlled startup or after every controlled shutdown in systems with two safety valves. It operates with a supply voltage of 220–240 V and has a storage temperature range of -15 to 40 °C. The device features screw terminals with a cross-section of 2.5 mm², a maximum switching current of 5 A, and an IP40 protection class. It is housed in impact-resistant plastic and weighs 0.485 kg. The test period is adjustable from 100 to 600 seconds, and it requires an external pressure switch for verification.
Further details
| Ambient temperature | -15 to +60°C (5 to 140°F), no condensation permitted |
|---|---|
| Application | tightness test before every controlled startup or after every controlled shut-down in systems with 2 safety valves |
| Enclosure | IP 40 |
| Fusing | fine-wire fuse 5 a, slow-acting, h pursuant to iec 127 |
| Mains voltage | 220/240 V AC, 50/60 Hz |
| Remote reset | by applying mains voltage (terminal 5) |
| Reset | using a button on the device |
| Test period tP | TC 410-1: 10 to 60 s, adjustable |
| Testing mode | testing before or after burner run |
Choosing and fitting
Parts of this type are selected by matching the supply voltage, test period range, and terminal specifications to the existing system. The device must be installed with proper cable glands (M16 plastic) and connected to an external pressure switch mounted between the valves. Ensure the ambient temperature and storage conditions are within specified limits. The housing has 5 knock-out holes for cable entry, and the unit should be mounted securely to avoid vibration.
Signs of failure
Common failures include malfunction of the internal relay or fuse, leading to the burner not starting or shutting down unexpectedly. If the external pressure switch fails, the tightness test may not complete, causing a lockout. Check the fuse (5 A slow-acting) and the pressure switch connections. Also, verify that the test period setting is correct and that the device is not exposed to condensation or extreme temperatures.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Protection class (IP) | IP40 |
| Storage temperature | -15–40 °C |
| Weight | 0.485 g |
| TC test period tP | 100–600 s |
| Air pressure switch verification | external pressure switch |
| Terminal type | screw terminals |
| Terminal cross-section | 2.5 mm2 |
| Switching current | max. 5 |
| Housing material | impact-resistant plastic |
| Gas type | dependent on external pressure switch |
| Cable gland | M16 plastic cable glands |
| Knock-out holes | 5 |
| Net weight | 0.485 kg |
Part numbers
| SKU | 84765820 |
|---|---|
| Additional article | 624.103.066 |