{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Kromschroder Burner control unit IFS135B-5/1/1T 84344510

SKU 84344510 Model IFS135B-5/1/1T Brand Kromschroder

Photos

no photo yet

Key specifications

Supply voltage220–240 V
Protection class (IP)IP40
Body materialimpact resistant plastic
Gas valve + GPS connection2.0
Ambient temperature-20–60 °C
Weight390 g
Fuelgas
connection_typeplug-in
Safety standardEN 298
Flame detection methods supportedionization probe or UV-cell
Safety featurereset button with fault indication
Installation positionarbitrary
Actuator typerelay contact
Connector typeplug socket with terminals
Operating principleelectromechanical
External fuse2 A
Flame monitoringionization probe or UV-cell
Ignition typedirect or pilot ignition
Operating voltage220/240 V
Housing typeimpact resistant plastic
Microprocessor-basedno
Mounting positionarbitrary
Net weight0.39 kg
all specifications (23) ↓
1580.70 EUR
1437.00EUR
in stock · 1

incl. 21% VAT · 1187.60 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Kromschroder IFS135B-5/1/1T is an electromechanical burner control unit for gas burners, suitable for ignition and flame monitoring via ionization probe or UV-cell. It operates on 220–240 V supply voltage, has a relay contact output for ignition transformer and valves, and supports direct or pilot ignition. The unit features a reset button with fault indication, is housed in impact-resistant plastic with IP40 protection, and weighs 390 g. It complies with EN 298 safety standard and is designed for ambient temperatures from -20 to 60 °C.

Further details

Cable glandPG 9
CertificationEC type tested and certified pursuant to the gas appliances directive (90/396/eec) in conjunction with EN 298
Climateno condensation permitted
Contact ratingMax. 1 A per output
EnclosureIP 40 pursuant to IEC 529
Flame controlSensor voltage: 220 V AC
Fuse in unitF1: 2 A, semi time-lag E, pursuant to DIN 41571 V/EN 60127-1
Installation positionArbitrary
Mains voltage220/240 V, 50/60 Hz
Power consumptionApprox. 18 VA
Reaction time< 1 s
Reset buttonMax. number of operating cycles: 1000
Sensor current> 1 µA
Signal inputRemote reset
Total loadMax. 2 A

Choosing and fitting

When selecting a replacement control box of this type, verify the supply voltage (e.g., 220–240 V), flame detection method (ionization or UV-cell), and the number of valve connections. Ensure the mounting position is arbitrary as per the original, and check the connector type (plug socket with terminals) to match the existing wiring. The external fuse rating (2 A) and protection class (IP40) must also be compatible with the application.

Signs of failure

Typical failures of such control units include failure to ignite, intermittent flame signal loss, or lockout indicated by the reset button. If the burner does not start or shuts down unexpectedly, check the flame sensor (ionization probe or UV-cell) for contamination or damage, and verify the supply voltage and fuse integrity. A faulty unit may also show no response to reset attempts.

All specifications

Supply voltage220–240 V
Protection class (IP)IP40
Body materialimpact resistant plastic
Gas valve + GPS connection2.0
Ambient temperature-20–60 °C
Weight390 g
Fuelgas
connection_typeplug-in
Safety standardEN 298
Flame detection methods supportedionization probe or UV-cell
Safety featurereset button with fault indication
Installation positionarbitrary
Actuator typerelay contact
Connector typeplug socket with terminals
Operating principleelectromechanical
External fuse2 A
Flame monitoringionization probe or UV-cell
Ignition typedirect or pilot ignition
Operating voltage220/240 V
Housing typeimpact resistant plastic
Microprocessor-basedno
Mounting positionarbitrary
Net weight0.39 kg

Part numbers

SKU84344510
Additional article624.103.041
ModelIFS135B-5/1/1T