Siemens Electromechanical burner control LAL2.25
SKU LAL2.25
Brand Siemens
Photos
Key specifications
| Supply voltage | AC |
|---|---|
| Safety time | 5 s |
| Interval between voltage application to terminals | 7.5 s |
| Interval between voltage switching at terminals | 7.5 s |
| Post-purge | 15 |
| Fan motor start delay | 2.5 s |
| Start-up sequence duration | 47 s |
| Fuel | oil |
| Air supply | forced draft |
| Cycle type | intermittent |
| Firing stages | multi-stage or modulating |
| Safety feature | manual reset lockout |
| Valve control type | electromechanical |
| Time after ignition (ignition transformer connected to terminal) | 15 s |
| Pre-purge time | 22.5 s |
| Pre-ignition time | 2.5 s |
1111.40 EUR
1010.36EUR
in stock · 2
incl. 21% VAT · 835.01 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This electromechanical control box starts and supervises multi-stage or modulating forced-draft oil burners with intermittent operation and manual reset lockout. It applies AC supply voltage to the fan motor after a 2.5 s delay, performs a 22.5 s pre-purge, then energizes the ignition transformer for 15 s. The safety time is 5 s; the intervals between voltage applications and between voltage switchings are 7.5 s each, and post-purge lasts 15 s. The complete start-up sequence takes 47 s, with pre-ignition time 2.5 s.
Further details
| Air pressure switch verification | functional test of the air pressure relay during start-up and operation |
|---|---|
| Flame Detector | photoresistive sensor (QRB1…) and selenium photocell (RAR...) |
Choosing and fitting
When selecting a replacement control box of this type, match the exact series and type designation, supply voltage, required safety time, pre-purge time, and flame-detection method of the burner. Verify the voltage rating and the base or plug pattern to ensure physical fit; controls within one series are not interchangeable if the safety-time setting differs. Some burners are fitted with electronic control boards instead; those boards are matched to the boiler model and are not field-interchangeable with a traditional control box. Use the part number on the existing control as the only certain reference if the burner documentation is unavailable.
All specifications
| Supply voltage | AC |
|---|---|
| Safety time | 5 s |
| Interval between voltage application to terminals | 7.5 s |
| Interval between voltage switching at terminals | 7.5 s |
| Post-purge | 15 |
| Fan motor start delay | 2.5 s |
| Start-up sequence duration | 47 s |
| Fuel | oil |
| Air supply | forced draft |
| Cycle type | intermittent |
| Firing stages | multi-stage or modulating |
| Safety feature | manual reset lockout |
| Valve control type | electromechanical |
| Time after ignition (ignition transformer connected to terminal) | 15 s |
| Pre-purge time | 22.5 s |
| Pre-ignition time | 2.5 s |
Part numbers
| SKU | LAL2.25 |
|---|---|
| Additional article | 884.124.005 |