Siemens Electromechanical burner automatic controller LAL2.65
SKU LAL2.65
Brand Siemens
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 5 s |
| Flame detector type | QRB1..., RAR... |
| Post-purge | 15 |
| Fuel | oil |
| Firing stages | multi-stage or modulating |
| Air supply | forced-draught |
| Cycle type | intermittent operation |
| Valve control type | electromechanical |
| Burner capacity | medium and high |
| Start-up sequence duration | 91 s |
| Fan motor start delay | 2.5 s |
| Interval between voltage application to terminals | 7.5 s |
| Interval between voltage switching at terminals | 7.5 s |
| Pre-purge time | 66.5 s |
| Pre-ignition time | 2.5 s |
1323.10 EUR
1202.82EUR
in stock · 1
incl. 21% VAT · 994.07 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This electromechanical burner automatic controller (Siemens LAL2.65) is used for start-up and control of forced-draught oil burners of medium and high capacity. It is suited to multi-stage or modulating burners in intermittent operation, with electromechanical valve control. Air pressure is monitored via a functional check of the air pressure relay during start-up and operation. Yellow flame is monitored by a photoresistive sensor QRB1..., blue flame by a sensor RAR... with selenium photocell. Its operating values include supply voltage 230 V, safety time 5 s, pre-purge time 66.5 s, pre-ignition time 2.5 s, post-purge time 15 s, and start-up sequence duration 91 s.
Further details
| Air Pressure Switch Verification | functional check of air pressure relay during start-up and operation |
|---|
Choosing and fitting
When replacing a control box of this class, the exact series and type designation of the original unit must be known. Supply voltage, safety time, and pre-purge time are critical parameters that must match. The flame detection method (ionisation, UV, or IR) and the base or plug pattern also determine compatibility. Controls of this type are normally not interchangeable between series, even within the same brand. A replacement with a different safety time is a safety hazard, not merely a compatibility issue.
All specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 5 s |
| Flame detector type | QRB1..., RAR... |
| Post-purge | 15 |
| Fuel | oil |
| Firing stages | multi-stage or modulating |
| Air supply | forced-draught |
| Cycle type | intermittent operation |
| Valve control type | electromechanical |
| Burner capacity | medium and high |
| Start-up sequence duration | 91 s |
| Fan motor start delay | 2.5 s |
| Interval between voltage application to terminals | 7.5 s |
| Interval between voltage switching at terminals | 7.5 s |
| Pre-purge time | 66.5 s |
| Pre-ignition time | 2.5 s |
Part numbers
| SKU | LAL2.65 |
|---|---|
| Additional article | 884.124.132 |
| Type designation | QRB1 |
| Type designation | RAR |