Siemens Burner automation LME21.330C2

SKU LME21.330C2 Brand Siemens

Photos

Key specifications

Flame detection methods supportedionisation, uv, or ir
Cycle typeintermittent
Firing stagessingle-stage or two-stage
Fuelgas
Application typeindustrial or commercial burners
Digital signal processingyes
Undervoltage detectionyes
Air pressure monitoringon
Remote reset signalyes
Fault and operational status indicationyes
Manual resetyes
Air pressure switch verificationyes
Controlled componentsignition transformer, fuel valve, fan
Driven componentsignition transformer, fuel valve, fan
Flame safeguardflame safeguard
Manufacturer codeLME21.330C2
Interchangeabilitynot interchangeable across series
Compatibility noteverify the existing control's specifications
Lockout on flame detection failureyes
all specifications (19) ↓
187.42 EUR
170.38EUR
in stock · 3

incl. 21% VAT · 140.81 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Siemens LME21.330C2 is a burner control box (flame safeguard) for gas burners in industrial or commercial applications. It supports flame detection with ionisation, UV, or IR sensors and operates in intermittent cycle mode as a single-stage or two-stage gas burner control. It controls and drives the ignition transformer, fuel valve, and fan, while monitoring air pressure and verifying the air pressure switch. The unit features digital signal processing, undervoltage detection, remote reset signal, fault status indication, and manual reset. It locks out on flame failure. Because it is not interchangeable across series, verify the existing control's specifications before replacement.

Choosing and fitting

Burner control boxes of this type are selected by matching the exact series and type designation of the original. Key parameters to compare are supply voltage, pre-purge and safety times, flame detection method, and base or plug pattern. These controls are not interchangeable across series even within the same brand; a mismatch in safety times or voltage creates a safety hazard. Before ordering, verify the existing control's specifications, particularly the safety time rating and the connector layout, to ensure a direct replacement.

All specifications

Flame detection methods supportedionisation, uv, or ir
Cycle typeintermittent
Firing stagessingle-stage or two-stage
Fuelgas
Application typeindustrial or commercial burners
Digital signal processingyes
Undervoltage detectionyes
Air pressure monitoringon
Remote reset signalyes
Fault and operational status indicationyes
Manual resetyes
Air pressure switch verificationyes
Controlled componentsignition transformer, fuel valve, fan
Driven componentsignition transformer, fuel valve, fan
Flame safeguardflame safeguard
Manufacturer codeLME21.330C2
Interchangeabilitynot interchangeable across series
Compatibility noteverify the existing control's specifications
Lockout on flame detection failureyes

Part numbers

SKULME21.330C2
Additional article884.124.070