Siemens Control box LME39.100C2

SKU LME39.100C2 Brand Siemens

Photos

Key specifications

Lockout on flame detection failureLockout
Fuelgas
Firing stages1- or 2-stage
Cycle typeintermittent
Remote reset signalRemote electrical restart capability
Undervoltage detectionYes
Restart limitationLimited
Digital signal processingYes, precise sequence control
Maximum continuous operation time24 hours
all specifications (9) ↓
272.46 EUR
247.69EUR
in stock · 1

incl. 21% VAT · 204.70 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This is a Siemens LME39.100C2 control box for gas burners. It supports 1- or 2-stage burners and operates on an intermittent cycle with a maximum continuous operation time of 24 hours. It locks out on flame failure and offers remote electrical restart capability. It includes undervoltage detection, limited restart attempts, and digital signal processing for precise sequence control.

Further details

Air Pressure MonitoringFunctional check of air pressure relay during start-up and operation
Driven ComponentsIgnition transformer, fuel valve, fan relay
Flame DetectorIonization electrode, QRA flame sensor (with AGQ3), or QRC blue flame sensor
InterchangeabilityNot interchangeable across series within the same brand
Monitored InputsAir pressure switches and temperature limits
Operating sequencePre-purge, ignition spark, fuel valve opening, flame proving
Status indicationMulti-color: fault, operational messages, flame presence

Choosing and fitting

Replacement of this type of control box requires matching the exact series designation, supply voltage, safety time, pre-purge duration, flame detection method (ionisation, UV, or IR), and base or plug pattern. Controls from different series are not interchangeable even within the same brand; a mismatched safety time is a genuine safety hazard. Before installation, verify that the existing wiring base corresponds to the plug pattern and that the programmed safety times fit the burner design. Always confirm against the burner documentation.

All specifications

Lockout on flame detection failureLockout
Fuelgas
Firing stages1- or 2-stage
Cycle typeintermittent
Remote reset signalRemote electrical restart capability
Undervoltage detectionYes
Restart limitationLimited
Digital signal processingYes, precise sequence control
Maximum continuous operation time24 hours

Part numbers

SKULME39.100C2
Additional article884.124.080