Brahma Electronic control board 357.1M001 16021500
SKU 16021500
Model 357.1M001
Brand Brahma
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Flame detection method | ionisation, uv or ir |
| Interchangeability | not interchangeable across series |
| Frequency | 50–60 Hz |
| Application | modern wall-hung boilers |
| Safety feature | flame safeguard |
| Application type | electronic control board (PCB) |
| Behaviour in the event of flame failure during operation | board enters lockout |
| Catalogue article numbers | 246.568.002 |
| Output drives | fan, ignition transformer, gas valve |
| Control functions | ignition and safety sequence |
| Safety times | pre-purge and safety times |
| Temperature sensor inputs | temperature sensors |
| Combustion chamber type | open or closed |
| Burner type | atmospheric gas burner |
663.64 EUR
603.31EUR
in stock · 1
incl. 21% VAT · 498.60 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is a Brahma electronic control board (PCB) for atmospheric gas burners in modern wall-hung boilers. It operates on 230 V and 50–60 Hz. The board performs the ignition and safety sequence, driving the fan, ignition transformer, and gas valve. It uses ionisation, UV, or IR flame detection and includes flame safeguard protection. If flame is not confirmed, the board enters lockout. It accepts temperature sensor inputs and is suitable for open or closed combustion chambers.
Further details
| Air Pressure Switch Sensing | reads air pressure switch and flame signal, energises ignition transformer |
|---|---|
| Application | wall-mounted boilers with open or closed combustion chamber with atmospheric gas burner |
| Flame monitoring function | burner control (flame safeguard) that receives heat demand signal, starts fan for pre-purge, reads air pressure switch and flame signal, energises ignition transformer during ignition phase, opens gas valve if flame is proved within safety time, enters loc |
| Modulation Actuator Drive | fan speed and gas valve or air damper |
| Sensing Inputs | air pressure switch and flame signal |
Choosing and fitting
Parts of this type are selected by the exact series and type designation on the original board, as well as supply voltage, safety and pre-purge times, and flame detection method. The physical base or plug pattern must also match. Such boards are generally not interchangeable across series, even within the same brand, because a mismatched safety time creates a system hazard. Always compare the original manufacturer code and catalogue number, and consult the boiler manufacturer's documentation for compatibility.
All specifications
| Supply voltage | 230 V |
|---|---|
| Flame detection method | ionisation, uv or ir |
| Interchangeability | not interchangeable across series |
| Frequency | 50–60 Hz |
| Application | modern wall-hung boilers |
| Safety feature | flame safeguard |
| Application type | electronic control board (PCB) |
| Behaviour in the event of flame failure during operation | board enters lockout |
| Catalogue article numbers | 246.568.002 |
| Output drives | fan, ignition transformer, gas valve |
| Control functions | ignition and safety sequence |
| Safety times | pre-purge and safety times |
| Temperature sensor inputs | temperature sensors |
| Combustion chamber type | open or closed |
| Burner type | atmospheric gas burner |
Part numbers
| SKU | 16021500 |
|---|---|
| Additional article | 246.568.002 |
| Model | 357.1M001 |