Brahma Electronic control board (PCB) FC E32C 37430030
SKU 37430030
Model FC E32C
Brand Brahma
Photos
Key specifications
| Safety standard | enforces the safety times |
|---|---|
| Fan control | starts the fan |
| Thermal resistance | high |
| Insulation durability | durable |
| Vibration resistance | resistant |
| Flame monitoring | monitors the flame signal |
| Model specific matching | matched to the specific model |
| Pre-purge sequence | starts the fan for pre-purge |
| Air pressure switch check | checks the air pressure switch |
| Ignition transformer activation | activates the ignition transformer |
| Fuel valve opening | opens the fuel valve |
| Integrated into appliance | integrated into the appliance |
| Physical layout | base or plug pattern |
| Manufacturer code | 37430030 |
| Name (English) | Brahma 37430030 FC E32C module |
| Name (English) original | Brahma 37430030 FC E32C module |
| SKU (English) original | 37430030, 246.568.010 |
| Ignition sequence | manages the ignition sequence |
| Safety time | enforces safety times |
| Heat demand signal | receives the heat demand signal |
207.64 EUR
188.76EUR
in stock · 2
incl. 21% VAT · 156.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma 37430030 FC E32C module is an electronic control board (PCB) designed for precise control of gas burner valves. It manages the ignition sequence, enforces safety times, and monitors the flame signal. The board receives the heat demand signal, starts the fan for pre-purge, checks the air pressure switch, activates the ignition transformer, and opens the fuel valve. It features high thermal resistance, durable insulation, and vibration resistance. This module is integrated into the appliance and matched to the specific model.
Further details
| Flame safeguard | burner control-also called a flame safeguard |
|---|---|
| Flame signal detection | via ionisation, uv, or ir detection |
| Key parameters | exact series and type designation, supply voltage, safety and pre-purge times, and the flame detection method |
| Lockout condition | if no flame is proved within the programmed safety time |
| Lockout on no flame | locks out if no flame is proved within the programmed safety time |
| No further details | no further details on compatibility, dimensions, or ratings are available from the catalogue entry |
| Not interchangeable across series | controls are normally not interchangeable across series |
| Physical fit verification | must match the boiler's wiring harness |
| Replacement verification | verify that it is the correct replacement for the original part by comparing the catalogue article and manufacturer code against the appliance documentation |
| Safety hazard mismatch | a mismatched safety time creates a safety risk |
| Safety risk | a mismatched safety time creates a safety risk |
| Selection criteria | exact series and type designation, supply voltage, safety and pre-purge times, and the flame detection method |
| Verification required | verify that it is the correct replacement for the original part by comparing the catalogue article and manufacturer code against the appliance documentation |
Choosing and fitting
Parts of this type are selected by matching the exact series and type designation, supply voltage, safety and pre-purge times, and flame detection method. The physical layout—base or plug pattern—must match the boiler's wiring harness. Compare the catalogue article and manufacturer code against the appliance documentation to verify correct replacement.
Signs of failure
When items of this kind fail, the burner may not start or may lock out if no flame is proved within the programmed safety time. The equipment may show error codes related to ignition or flame detection. Check the control board for signs of damage, and verify that the flame signal and safety times are functioning correctly.
Fits equipment
Brahma FC E32CBrahma 37430030Brahma 246.568.010
All specifications
| Safety standard | enforces the safety times |
|---|---|
| Fan control | starts the fan |
| Thermal resistance | high |
| Insulation durability | durable |
| Vibration resistance | resistant |
| Flame monitoring | monitors the flame signal |
| Model specific matching | matched to the specific model |
| Pre-purge sequence | starts the fan for pre-purge |
| Air pressure switch check | checks the air pressure switch |
| Ignition transformer activation | activates the ignition transformer |
| Fuel valve opening | opens the fuel valve |
| Integrated into appliance | integrated into the appliance |
| Physical layout | base or plug pattern |
| Manufacturer code | 37430030 |
| Name (English) | Brahma 37430030 FC E32C module |
| Name (English) original | Brahma 37430030 FC E32C module |
| SKU (English) original | 37430030, 246.568.010 |
| Ignition sequence | manages the ignition sequence |
| Safety time | enforces safety times |
| Heat demand signal | receives the heat demand signal |
Part numbers
| SKU | 37430030 |
|---|---|
| Additional article | 246.568.010 |
| Model | FC E32C |