{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Electronic control board (PCB) FC E32C 37430030

SKU 37430030 Model FC E32C Brand Brahma

Photos

Key specifications

Safety standardenforces the safety times
Fan controlstarts the fan
Thermal resistancehigh
Insulation durabilitydurable
Vibration resistanceresistant
Flame monitoringmonitors the flame signal
Model specific matchingmatched to the specific model
Pre-purge sequencestarts the fan for pre-purge
Air pressure switch checkchecks the air pressure switch
Ignition transformer activationactivates the ignition transformer
Fuel valve openingopens the fuel valve
Integrated into applianceintegrated into the appliance
Physical layoutbase or plug pattern
Manufacturer code37430030
Name (English)Brahma 37430030 FC E32C module
Name (English) originalBrahma 37430030 FC E32C module
SKU (English) original37430030, 246.568.010
Ignition sequencemanages the ignition sequence
Safety timeenforces safety times
Heat demand signalreceives the heat demand signal
all specifications (20) ↓
207.64 EUR
188.76EUR
in stock · 2

incl. 21% VAT · 156.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma 37430030 FC E32C module is an electronic control board (PCB) designed for precise control of gas burner valves. It manages the ignition sequence, enforces safety times, and monitors the flame signal. The board receives the heat demand signal, starts the fan for pre-purge, checks the air pressure switch, activates the ignition transformer, and opens the fuel valve. It features high thermal resistance, durable insulation, and vibration resistance. This module is integrated into the appliance and matched to the specific model.

Further details

Flame safeguardburner control-also called a flame safeguard
Flame signal detectionvia ionisation, uv, or ir detection
Key parametersexact series and type designation, supply voltage, safety and pre-purge times, and the flame detection method
Lockout conditionif no flame is proved within the programmed safety time
Lockout on no flamelocks out if no flame is proved within the programmed safety time
No further detailsno further details on compatibility, dimensions, or ratings are available from the catalogue entry
Not interchangeable across seriescontrols are normally not interchangeable across series
Physical fit verificationmust match the boiler's wiring harness
Replacement verificationverify that it is the correct replacement for the original part by comparing the catalogue article and manufacturer code against the appliance documentation
Safety hazard mismatcha mismatched safety time creates a safety risk
Safety riska mismatched safety time creates a safety risk
Selection criteriaexact series and type designation, supply voltage, safety and pre-purge times, and the flame detection method
Verification requiredverify that it is the correct replacement for the original part by comparing the catalogue article and manufacturer code against the appliance documentation

Choosing and fitting

Parts of this type are selected by matching the exact series and type designation, supply voltage, safety and pre-purge times, and flame detection method. The physical layout—base or plug pattern—must match the boiler's wiring harness. Compare the catalogue article and manufacturer code against the appliance documentation to verify correct replacement.

Signs of failure

When items of this kind fail, the burner may not start or may lock out if no flame is proved within the programmed safety time. The equipment may show error codes related to ignition or flame detection. Check the control board for signs of damage, and verify that the flame signal and safety times are functioning correctly.

Fits equipment

Brahma FC E32CBrahma 37430030Brahma 246.568.010

All specifications

Safety standardenforces the safety times
Fan controlstarts the fan
Thermal resistancehigh
Insulation durabilitydurable
Vibration resistanceresistant
Flame monitoringmonitors the flame signal
Model specific matchingmatched to the specific model
Pre-purge sequencestarts the fan for pre-purge
Air pressure switch checkchecks the air pressure switch
Ignition transformer activationactivates the ignition transformer
Fuel valve openingopens the fuel valve
Integrated into applianceintegrated into the appliance
Physical layoutbase or plug pattern
Manufacturer code37430030
Name (English)Brahma 37430030 FC E32C module
Name (English) originalBrahma 37430030 FC E32C module
SKU (English) original37430030, 246.568.010
Ignition sequencemanages the ignition sequence
Safety timeenforces safety times
Heat demand signalreceives the heat demand signal

Part numbers

SKU37430030
Additional article246.568.010
ModelFC E32C