Honeywell PCB (control board) SM11444U

SKU SM11444U Brand Honeywell

Photos

Key specifications

Flame detection methodionisation electrode
Application typecentral control unit
Modulation actuator drivefan speed and valve control
Air pressure switch sensingair pressure switch
NTC sensor inputtemperature sensors
Functionconventional burner control (flame safeguard)
all specifications (6) ↓
132.20 EUR
120.18EUR
in stock · 2

incl. 21% VAT · 99.32 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This control board (SKU SM11444U) is a central control unit for wall-hung gas boilers. It performs conventional burner control (flame safeguard), detecting flame via an ionisation electrode. It reads an air pressure switch and accepts NTC temperature sensors, and it controls modulation through fan speed and valve control. It is designed for use in Baxi Main 24 Fi, Baxi Main 24i, Baxi Quasar Plus 24 Fi, and Baxi Quasar Plus 24i.

Further details

Applicationmodern wall-hung boilers and similar heating appliances
Application typeelectronic control board for wall-hung boilers and heating appliances
Control Functionsorchestration of the ignition and safety sequence
Flame Failure Behaviorboard locks out and signals a fault
Mounting patternbase or plug mounting pattern variants

Choosing and fitting

Control boards of this type are selected by matching the exact series and type designation of the original, along with supply voltage, safety and pre-purge times, and flame detection method. The physical mounting pattern (base or plug) also varies. Before ordering, verify that the manufacturer code and catalogue number on the existing board match exactly. Boards from different series within the same brand are normally not interchangeable if these parameters differ.

Signs of failure

During operation, the board initiates the fan for pre-purge, reads the air pressure switch, and checks flame via the ionisation electrode. If flame is not proven within the programmed safety time, the board locks out and signals a fault.

Fits equipment

Baxi MAIN 24 Fi, 24i. QUASAR PLUS 24 Fi, 24 iBaxi Main 24 FiBaxi Main 24 IBaxi Quasar Plus 24 FiBaxi Quasar Plus 24 IBaxi main 24 fiBaxi main 24iBaxi quasar plus 24 fiBaxi quasar plus 24 i

All specifications

Flame detection methodionisation electrode
Application typecentral control unit
Modulation actuator drivefan speed and valve control
Air pressure switch sensingair pressure switch
NTC sensor inputtemperature sensors
Functionconventional burner control (flame safeguard)

Part numbers

SKUSM11444U
Additional article534.568.702