Honeywell Control board / Electronic module SM11451U

SKU SM11451U Brand Honeywell

Photos

no photo yet

Key specifications

Control functionsparameter monitoring, actuator control, safety
Device typecontrol board / electronic module
Functionboiler control board
Design featuresoriginal honeywell configuration, industrial reliability
Model specific matchingspecific to boiler model
Flame detection methodionisation
Compatible boilersBaxi or Westen equipment
Revisiondifferent firmware or connector configuration
Catalogue number534.568.035
Manufacturer codeSM11451U
Electrical connectionconnector patterns, mounting arrangement model-specific
Mounting patternmodel-specific
Lockout on faultlockout on failure
all specifications (13) ↓
222.95 EUR
202.68EUR
in stock · 1

incl. 21% VAT · 167.50 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell SM11451U is a control board/electronic module for gas boilers, specifically designed for Baxi or Westen equipment. It performs parameter monitoring, actuator control (pump, valves), and safety functions. This board uses ionisation flame detection and is a revision of the SM11450U, with potential differences in firmware or connector configuration. It is identified by type designation CS0171B-LS and catalogue number 534.568.035.

Further details

Communication with componentsgas valve, ionisation electrode, fan, air pressure switch
Compatibility verificationvisual comparison, revision check, confirm replacement
Flame safeguard roleprimary controller in modern wall-hung boilers
Ignition sequencepre-purge, ignition, fuel admission, flame proving, lockout on failure
Ignition sequence managementmanage pre-purge, ignition, fuel admission, flame proving, and lockout on failure
Interchangeabilitymay be interchangeable only from a certain boiler revision
Modulationmay modulate output based on sensor feedback
Output drivesfan, gas valve, ignition transformer, pump
Replacement verificationcontact managers or provide photo of old board
Safety hazard mismatchusing a board intended for a different series or version can create a safety hazard
Safety time enforcementpre-purge, safety, and flame-proving times differ
Verification requiredverify exact manufacturer code and catalogue number against existing board

Choosing and fitting

Control boards of this type are selected by matching the exact manufacturer code and catalogue number to the existing board. The electrical connection and mounting pattern are model-specific, so visual comparison of connectors, jumpers, and fuses is essential. Verify the firmware revision matches your boiler's requirements, as boards may be interchangeable only from a certain boiler revision.

Signs of failure

When such boards fail, the boiler may lock out on fault, fail to ignite, or exhibit erratic operation of the fan, gas valve, or pump. Check for visible damage, loose connections, or blown fuses. If the board is suspected, compare its markings and revision with the original to ensure correct replacement.

Fits equipment

Baxi Westen

All specifications

Control functionsparameter monitoring, actuator control, safety
Device typecontrol board / electronic module
Functionboiler control board
Design featuresoriginal honeywell configuration, industrial reliability
Model specific matchingspecific to boiler model
Flame detection methodionisation
Compatible boilersBaxi or Westen equipment
Revisiondifferent firmware or connector configuration
Catalogue number534.568.035
Manufacturer codeSM11451U
Electrical connectionconnector patterns, mounting arrangement model-specific
Mounting patternmodel-specific
Lockout on faultlockout on failure

Part numbers

SKUSM11451U
Additional article534.568.035
Superseded numberSM11450U
Type designationCS0171B-LS