Honeywell PCB (control board) SM11462U

SKU SM11462U Model SM11462 Brand Honeywell

Photos

Key specifications

Replacement verificationverify against boiler's documentation
Safety timeno data
Flame detector typeionisation, uv, or ir
Ignition sequenceruns the ignition sequence
Lockout on faultlockout on failure
Flame monitoringreads the flame signal
Output drivestransformer, valve, and fan
Safety featuresafety issue if mismatched
Design featurescentral logic unit
Electrical connectionconnector pattern (base or plug)
Flame safeguard roleflame safeguard
Pre-purge functionpre-purge
Gas valve controlgas valve
Fan controlfan
all specifications (14) ↓
159.35 EUR
144.86EUR
in stock · 152

incl. 21% VAT · 119.72 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Honeywell PCB (control board) SM11462U is an electronic control board for Baxi boilers, model SM11462, type designation CS0263C. It runs the ignition sequence, performs pre-purge, monitors the flame via ionisation, UV, or IR, and drives the transformer, valve, and fan. It locks out on failure and acts as the central logic unit and flame safeguard. Electrical connection is via a connector pattern (base or plug). Verify compatibility against boiler documentation before ordering.

Further details

Compatible control typeconventional burner control or flame safeguard
Control operationsignition sequence, safety times, flame proving
Installation featurenot interchangeable across series or brands
Interface compatibilitycommunicates with gas valve, ignition transformer, fan, sensors
Model-specific matchingmatched to the specific boiler model
Mounting featuremodel-specific connector pattern and mounting arrangement
Selection criteriaexact series and type designation, supply voltage, safety and pre-purge times, flame detection method, connector pattern

Choosing and fitting

Parts of this type are selected by matching the exact series and type designation, supply voltage, safety and pre-purge times, flame detection method (ionisation, UV, or IR), and connector pattern (base or plug). A mismatched safety time or voltage is a safety issue. Always verify these parameters against the boiler's documentation before ordering.

Fits equipment

Baxi ECO Compact 1.14 F, 1.24, 1.24 F, 14 F, 18 F, 24, 24 F; ECO-5 Compact 1.14 F, 1.24, 1.24 F, 14 F, 18 F, 24, 24 F; ECO-5 COMPACT Baxi eco compact 1.14 f, 1.24, 1.24 f, 14 f, 18 f, 24.24 fBaxi eco-5 compact 1.14 f, 1.24, 1.24 f, 14 f, 18 f, 24, 24 fBaxi eco-5 compact 24 f gplBaxi eco-5 compact+ 1.24, + 24Baxi main-5 14 f, 18 f, 24 fBaxi pulsar e 1.24 f, e 24 fBaxi quasar e 18f, e 24f

All specifications

Replacement verificationverify against boiler's documentation
Safety timeno data
Flame detector typeionisation, uv, or ir
Ignition sequenceruns the ignition sequence
Lockout on faultlockout on failure
Flame monitoringreads the flame signal
Output drivestransformer, valve, and fan
Safety featuresafety issue if mismatched
Design featurescentral logic unit
Electrical connectionconnector pattern (base or plug)
Flame safeguard roleflame safeguard
Pre-purge functionpre-purge
Gas valve controlgas valve
Fan controlfan

Part numbers

SKUSM11462U
Additional article534.568.710
ModelSM11462
Type designationCS0263C