Description

An electronic control board for wall-mounted gas boilers. It serves as the main controller for ignition sequence and safety functions, handling pre-purge, ignition, fuel admission, flame proving, and lockout on failure. The board manages modulation by adjusting fan speed and gas valve output based on temperature sensor feedback. It is compatible with Baxi Main Four, Eco Four, and Fourtech models, and can replace part numbers JJJ005702450, 005702450, and 5702450. No adjustment is possible on the board itself.

Further details

Actuator typefan speed and gas valve output
Applicationwall-mounted gas boilers Baxi Main Four, Eco Four, FourTech
Article Numberscatalogue article 534.568.711, manufacturer code sm11469u
Compatible with boiler modelsBaxi Main Four, Eco Four, Fourtech
Control Functionspre-purge, ignition, fuel admission, flame proving, and lockout on failure
Firmware-based configurationsupply voltage and safety times set by firmware
Modulation Actuator Drivefan speed and gas valve output
Modulation controladjusts fan speed and gas valve output based on temperature sensor feedback
Output Drivesignition transformer, gas valve, fan, and sometimes the circulation pump

Choosing and fitting

Select a replacement by matching the control board to the specific boiler model; these boards are not interchangeable across different models, even within the same brand. Confirm the exact part number and the boiler model before ordering, as supply voltage and safety times are set by the board's firmware and must match the boiler's design parameters. No adjustment is possible on the board itself.

Signs of failure

When a control board fails, the boiler typically enters lockout mode and will not ignite. Common failure modes include loss of flame signal recognition, incorrect safety timing, or communication faults with temperature sensors. The equipment may show a fault code or fail to respond to the thermostat. If the board is mismatched to the boiler model, safety timing errors or valve control issues may occur.

Fits equipment

Baxi Main Four, Eco Four, FourtechBaxi Main FourBaxi Eco FourBaxi FourtechBaxi FourTech

All specifications

Interchangeabilitynot interchangeable across different models
Applicationwall-mounted gas boilers
Application typemain controller
Behaviour in the event of flame failure during operationlockout on failure
NTC sensor inputtemperature sensor feedback
Replaces part numbersjjj005702450, 005702450, 5702450
Safety timesset by board's firmware
Adjustment possibleNo

Part numbers

SKUSM11469U
Additional article534.568.711
Superseded numberJJJ005702450