EBM PAPST Fan RLA97/0034-3612 55667.13005
SKU 55667.13005
Model RLA97/0034-3612
Brand EBM PAPST
Photos
Key specifications
| Brand | EBM PAPST |
|---|---|
| Type | Fan |
| SKU | 55667.13005 |
| Additional article | 375.145.013 |
| Model | RLA97/0034-3612 |
| OEM equivalent | 190262 |
| OEM equivalent | 0020200682 |
| Fits | EBM PAPST RLA97/0034-3612, Protherm 35KTV20 Panther, Vaillant 190262, Protherm 0020200682 |
Specifications are being collected from the manufacturer's documentation.
672.16 EUR
611.05EUR
in stock · 2
incl. 21% VAT · 505.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is an EBM PAPST fan, model RLA97/0034-3612, SKU 55667.13005. It is a combustion air fan and flue gas exhauster used in modulating premix boilers. The fan supplies combustion air and, in room-sealed appliances, drives flue gases out of the system. It is listed as an OEM equivalent for Vaillant 190262 and Protherm 0020200682, and fits Protherm 35KTV20 Panther and Vaillant 35ktv20 Panther.
Further details
| Application | combustion air supply and flue gas drive in room-sealed appliances; firing rate control in modulating premix boilers |
|---|---|
| Common failure modes | worn bearings, impeller imbalance from dirt or deposits, a failed run capacitor, and speed feedback errors |
| Control Mode | mains on/off, PWM, or 0-10 V signal |
| Key Matching Parameters | air flow, pressure, outlet direction and orientation, impeller diameter, voltage, control mode, flange pattern |
Choosing and fitting
Replacement fans of this type are selected by matching air flow and pressure, outlet direction and orientation, impeller diameter, voltage, and control mode (mains on/off, PWM, or 0-10 V signal). The flange pattern must also align with the burner or boiler mounting. Before ordering, measure or compare the existing fan's dimensions and electrical connections to ensure a proper fit.
Signs of failure
Common failure modes for these fans include worn bearings, impeller imbalance from dirt or deposits, a failed run capacitor, and speed feedback errors. The boiler control may interpret speed feedback errors as an airflow fault, causing a lockout or reduced output. Check for unusual noise, vibration, and visible deposits on the impeller before ordering a replacement.
Fits equipment
Part numbers
| SKU | 55667.13005 |
|---|---|
| Additional article | 375.145.013 |
| Model | RLA97/0034-3612 |
| OEM equivalent | 190262 |
| OEM equivalent | 0020200682 |