{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Photocell FC7/A 18210018

SKU 18210018 Model FC7/A Brand Brahma

Photos

Key specifications

Detection principlephotocell
Cable length635 mm
Catalogue article numbers18210018, 4031.018, 246.901.016
Application typeluminous flames
Detection principlelight detection
FC7/A designationfc7/a blue
Flame detection methoddirect line-of-sight
all specifications (7) ↓
39.13 EUR
35.57EUR
in stock · 45

incl. 21% VAT · 29.40 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Brahma FC7/A photocell flame sensor with a 635 mm cable, designed for flame detection in luminous flames. It operates by light detection and requires direct line-of-sight to the flame. This model is identified by article numbers 18210018, 4031.018, and 246.901.016. It is compatible with Master 4031.018, Master BV680, Master MAX15TC, and Master MAX20TL air heaters.

Further details

Applicationflame detection on oil and industrial burners
Replacement checksame detection principle, cable length, connector, and mounting dimensions
Selection parametersdetection principle, spectral range, response time, cable length, connector type, mounting arrangement
Typical Failure Modescontaminated optical window, aged cell, damaged cable

Choosing and fitting

When selecting a replacement photocell of this type, ensure the detection principle (light detection), cable length, connector type, and mounting dimensions match the original component. The sensor must be positioned with a clear line-of-sight to the flame, typically in a viewing tube or sleeve. Verify the mounting arrangement and spectral response to match the burner control.

Signs of failure

Common failure modes include a contaminated optical window, an aged cell producing a weakened signal, or a damaged cable or sheath. Symptoms may include the burner failing to start or shutting down during operation due to lack of flame confirmation. Check the optical window for dirt or damage, and test the sensor's output signal.

Fits equipment

Master 4031.018Master BV680Master MAX15TCMaster MAX20TL

All specifications

Detection principlephotocell
Cable length635 mm
Catalogue article numbers18210018, 4031.018, 246.901.016
Application typeluminous flames
Detection principlelight detection
FC7/A designationfc7/a blue
Flame detection methoddirect line-of-sight

Part numbers

SKU18210018
Additional article246.901.016
ModelFC7/A