Honeywell Rectification flame amplifier R7847A1074/U
SKU R7847A1074/U
Brand Honeywell
Photos
Key specifications
| Weight | 70 g |
|---|---|
| Ambient temperature | -40–60 °C |
| Device type | solid-state removable amplifiers |
| Width | 91 mm |
| Height | 85 mm |
| Thickness (with base Q7800A) | 23 mm |
| Flame signal intensity range | 0–5 V |
| Compatible with | 7800 relay module |
| Orientation | configured for its own orientation |
| Operation type | dynamic self-checking |
| Flame detection methods | flame rectification |
| Compatible relay modules | 7800 series relay modules |
505.89 EUR
459.90EUR
in stock · 1
incl. 21% VAT · 380.08 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell R7847A1074/U is a solid-state, removable flame amplifier that operates on the principle of flame rectification. It is designed for use with Honeywell 7800 series relay modules, responding to input signals from a flame detector to indicate the presence of a flame. This dynamic self-checking amplifier measures flame signal intensity in the range of 0 to 5 V. It has dimensions of 91 mm width, 85 mm height, and 23 mm thickness, and weighs 70 g. The operating ambient temperature range is -40 to 60 °C. It connects to the relay module via an edge connector and is configured for its own orientation.
Further details
| Accessories | 123514A Flame Rectifier simulator. 203659 is an ultraviolet flame simulator |
|---|---|
| Dimensions | width - 91 mm, height - 85mm, thickness - 23mm |
| Flame signal control sockets | for measuring the voltage of the flame signal on the amplifier |
Choosing and fitting
Parts of this type are selected by ensuring compatibility with the specific relay module series and the flame detection method. The amplifier must match the relay module's connector type and orientation. Before ordering, verify the dimensions and mounting form to fit the existing enclosure. The flame signal intensity range and ambient temperature limits should also be considered for the application.
Signs of failure
When amplifiers of this kind fail, the burner may shut down or fail to start, often due to loss of flame signal detection. Symptoms include intermittent flame loss, false flame indications, or a complete lack of response to the flame detector. Check the amplifier's connections, the flame detector's condition, and the signal voltage to diagnose the issue.
Fits equipment
Honeywell 7800 series relay modules
All specifications
| Weight | 70 g |
|---|---|
| Ambient temperature | -40–60 °C |
| Device type | solid-state removable amplifiers |
| Width | 91 mm |
| Height | 85 mm |
| Thickness (with base Q7800A) | 23 mm |
| Flame signal intensity range | 0–5 V |
| Compatible with | 7800 relay module |
| Orientation | configured for its own orientation |
| Operation type | dynamic self-checking |
| Flame detection methods | flame rectification |
| Compatible relay modules | 7800 series relay modules |
Part numbers
| SKU | R7847A1074/U |
|---|---|
| Additional article | 534.868.043 |
| Type designation | 123514A |
| Type designation | 203659 |