Kromschroder UV flame detector UVC1L3G1A 84320302

SKU 84320302 Model UVC1L3G1A Brand Kromschroder

Photos

no photo yet

Key specifications

Detection principleUV
Distance between UV flame detector and flame300–400 mm
Clamping range of the connection terminals0.5–1.5 mm2
Weight1000 g
Ambient temperature-20–80 °C
Storage temperature-20–80 °C
Safety class1
materialAluminum
Sensing elementUV tube P578
Compatible control typeKromschroder BCU, PFU
Electrical connectionTerminals L and N
Service lifeApprox. 10,000 operating hours
Device typeUV flame detector
Frequency50–60 Hz
Cable length2000–100000 mm
Cycle typeIntermittent and continuous
Pollution degreeInternal: 2, External: 4
Designed lifetime10 years
Connection threadRP 1/2 internal thread
Cooling air connectionM20 cable gland
Supply voltage100–230 V
all specifications (21) ↓
2219.58 EUR
2017.80EUR
in stock · 1

incl. 21% VAT · 1667.60 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This UV flame detector from Kromschroder, model UVC1L3G1A, monitors flames emitting UV radiation. It is designed for use with Kromschroder BCU and PFU burner control units for both intermittent and continuous operation. The detector operates on a supply voltage of 100–230 V at 50–60 Hz and connects via RP 1/2 internal thread with an M20 cable gland. Its sensing element is a UV tube type P578, and it should be positioned 300–400 mm from the flame. The cable between the detector and the control unit can be 2000 to 100000 mm long. It has an aluminum housing, operates in ambient temperatures from -20 to 80 °C, and weighs 1000 g.

Further details

EnclosureIP 65
Housingaluminum
Lens typeSeries 1 quartz glass heat guard lens
Min. DC signal1 μA
Supply voltage100 to 230 V AC, 50/60 Hz (terminals L and N)
UV tubeP578, spectral range: 190 to 270 nm, max. sensitivity: 210 nm ± 10 nm

Fits equipment

Kromschroder BCU and PFU M20 cable glandKromschroder BCUKromschroder PFU

All specifications

Detection principleUV
Distance between UV flame detector and flame300–400 mm
Clamping range of the connection terminals0.5–1.5 mm2
Weight1000 g
Ambient temperature-20–80 °C
Storage temperature-20–80 °C
Safety class1
materialAluminum
Sensing elementUV tube P578
Compatible control typeKromschroder BCU, PFU
Electrical connectionTerminals L and N
Service lifeApprox. 10,000 operating hours
Device typeUV flame detector
Frequency50–60 Hz
Cable length2000–100000 mm
Cycle typeIntermittent and continuous
Pollution degreeInternal: 2, External: 4
Designed lifetime10 years
Connection threadRP 1/2 internal thread
Cooling air connectionM20 cable gland
Supply voltage100–230 V

Part numbers

SKU84320302
Additional article624.208.008
ModelUVC1L3G1A