Kromschroder Gas pressure regulator GDJ15R04-0L 03155031

SKU 03155031 Model GDJ15R04-0L Brand Kromschroder

Photos

Key specifications

Nominal diameter (DN)15 mm
Connection threadRp 1/2"
Max. inlet pressure400 mbar
Setting range5–160 mbar
Actuator typespring-loaded
Turndown10:1
Ambient temperature-20–60 °C
Design featurescompact size, low weight
Inlet pressure compensationyes
Compensation diaphragmyes
Standard setting12.5–25 mbar
Gas conditiondry, without condensate
connection_typeinternal thread
Applicationnatural gas, liquefied gas, air
Safety featuresafety diaphragm, zero closure
Operating principlediaphragm and spring set
all specifications (16) ↓
376.23 EUR
342.03EUR
in stock · 1

incl. 21% VAT · 282.67 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Spring-loaded gas pressure regulator with Rp 1/2" internal thread and 15 mm nominal diameter. It supplies natural gas, liquefied gas, or air (dry, without condensate) at outlet pressures from 5 to 160 mbar; the factory standard setting is 12.5–25 mbar. Maximum inlet pressure is 400 mbar. The design includes a safety diaphragm, a compensation diaphragm, and zero closure, with a 10:1 turndown. Operates over an ambient temperature range of -20 to 60 °C.

Further details

CertificationEN 88 Class A, Group 2, CE

Choosing and fitting

For this class of spring-loaded gas pressure regulators, replacement is selected by connection type (internal or external thread or flange), connection size, inlet pressure rating, outlet pressure range, and gas compatibility. Always check the flow direction arrow on the body. Before ordering, measure or compare the thread size and pressure range of the existing part; after installation, verify outlet pressure with a manometer and set it to the burner specification.

Signs of failure

Typical failures include a torn diaphragm, blocked gas filter, or seized adjusting spring. A torn diaphragm or seized spring produces unstable outlet pressure, which may cause the burner to surge or fail to hold the set point. A blocked filter shows as loss of pressure or flow. Check outlet pressure with a manometer, inspect the diaphragm and filter, and make sure the adjusting spring moves freely.

All specifications

Nominal diameter (DN)15 mm
Connection threadRp 1/2"
Max. inlet pressure400 mbar
Setting range5–160 mbar
Actuator typespring-loaded
Turndown10:1
Ambient temperature-20–60 °C
Design featurescompact size, low weight
Inlet pressure compensationyes
Compensation diaphragmyes
Standard setting12.5–25 mbar
Gas conditiondry, without condensate
connection_typeinternal thread
Applicationnatural gas, liquefied gas, air
Safety featuresafety diaphragm, zero closure
Operating principlediaphragm and spring set

Part numbers

SKU03155031
Additional article624.658.070
ModelGDJ15R04-0L